Main
pressure actuator
Diaphragm
Fluid connection type
G 1/4 (female) conforming to ISO 228
[ui] rated insulation voltage
500 V conforming to EN/IEC 60947-1
controlled fluid
Air (0…55 °C)
Fresh water (0…55 °C)
Sea water (0…55 °C)
Pressure switch type of operation
Regulation between 2 thresholds
pressure sensor name
XMX
pressure rating
12 bar
pressure sensor type
Electromechanical pressure sensor
Complementary
[in] rated current
3 A (Ue = 120 V), AC-15, B300
1.5 A (Ue = 240 V), AC-15, B300
0.1 A (Ue = 250 V), DC-13, R300
local display
Without
Product certifications
CSA
UL
CCC
Adjustable range of switching point on falling pressure
0.3…10.3 bar
Handle front plate colour
106 mm
[uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-1
Adjustable range of switching point on rising pressure
1.3…12 bar
cable entry
2 entries tapped for Pg 13.5 cable gland conforming to NF C 68-300
Enclosure material
PC impregnated with Lexan 500R
Contacts type and composition
1 C/O snap action
Electrical shock protection class
Class I conforming to IEC 536
width (w)
57 mm
Colour of cover
Black opaque
Destruction pressure
30 bar
Electrical circuit type
Control circuit
Net weight
0.43 kg
setting
Internal
Operating position
Any position
depth
97.5 mm
mechanical durability
1000000 cycles
electrical durability
1000000 cycles, 50/60 Hz, AC-15, 240 V / 3 A, Ith = 10 A
repeat accuracy
3.5 %
Materials in contact with fluid
Chromated zinc alloy
Canvas covered nitrile
electrical connection
Screw-clamp terminals, clamping capacity: 1 x 1...2 x 2.5 mm²
Maximum operating rate
10 cyc/mn
Maximum permissible accidental pressure
27 bar
Maximum permissible pressure - per cycle
15 bar
Possible differential minimum at high setting
1.7 bar
Possible differential minimum at low setting
1 bar
Scale type
Fixed differential
Short-circuit protection
10 A cartridge fuse, type gG (gl)
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP54 conforming to EN/IEC 60529
Range of product
Telemecanique Pressure sensors XM
ambient air temperature for operation
-25…55 °C
standards
EN/IEC 60947-5-1
CE
protective treatment
TC