Main
pressure actuator
Diaphragm
Fluid connection type
G 3/8 (female) conforming to ISO 228
3 x G 1/4 (female)
product specific application
-
[ui] rated insulation voltage
500 V conforming to EN/IEC 60947-1
controlled fluid
Air (0…70 °C)
Fresh water (0…70 °C)
Sea water (0…70 °C)
Pressure switch type of operation
Regulation between 2 thresholds
pressure sensor name
XMP
pressure rating
12 bar
pressure sensor type
Electromechanical pressure sensor
Complementary
Control type
ON/OFF knob
local display
Without
Product certifications
EAC
Adjustable range of switching point on falling pressure
0.3…10.3 bar
Adjustment range high setting
1.3…12 bar
Handle front plate colour
138 mm
[uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-1
cable entry
2 entries incorporating Pg 16 plastic cable gland, cable outer diameter: 12…15 mm conforming to NF C 68-300
Enclosure material
PA impregnated with fibreglass
Contacts type and composition
3 NC snap action
Electrical shock protection class
Class I conforming to IEC 60536
Sale per indivisible quantity
1
width (w)
57 mm
Destruction pressure
30 bar
Electrical circuit type
Power circuit
setting
Nut
Operating position
Any position
terminal block type
6 terminals
depth
98 mm
mechanical durability
1000000 cycles
electrical durability
1000000 cycles 1.5 kW, operating rate <10 cyc/mn, load factor: 0.4, 400 V AC 3 phases
500000 cycles 3 kW, operating rate <10 cyc/mn, load factor: 0.4, 400 V AC 3 phases
600000 cycles 1.5 kW, operating rate <10 cyc/mn, load factor: 0.4, 230 V AC 3 phases
700000 cycles 2.2 kW, operating rate <10 cyc/mn, load factor: 0.4, 400 V AC 3 phases
repeat accuracy
3.5 %
Materials in contact with fluid
Chromated zinc alloy
Canvas covered nitrile
electrical connection
Screw-clamp terminals, clamping capacity: minimum : 2 x 4 mm²
Maximum operating rate
10 cyc/mn
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
25 MOhm conforming to NF C 93-050 method A
Possible differential maximum at high setting
8.4 bar
Possible differential minimum at high setting
1.7 bar
Possible differential minimum at low setting
1 bar
Shock resistance
50 gn conforming to IEC 60068-2-27
Scale type
Adjustable differential
Type of decompression valve
Straight valve instant connection
Terminals description iso n°1
(1-2)NC
(3-4)NC
(5-6)NC
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP54 conforming to EN/IEC 60529
Range of product
Telemecanique Pressure sensors XM
ambient air temperature for operation
-25…70 °C
standards
EN/IEC 60947-4-1
CE
vibration resistance
3 gn conforming to IEC 60068-2-6 (f = 10…500 Hz)