Main
Fluid connection type
G 1/4A (male) conforming to DIN 3852-E
controlled fluid
Air (-30…135 °C)
Fresh water (0…135 °C)
Hydraulic oil (-30…135 °C)
Gas (-30…135 °C)
Refrigeration fluid (-30…135 °C)
Type of packing
Individual
pressure sensor name
XMLP
pressure rating
250 bar
pressure sensor type
Pressure transmitter
Complementary
length [l]
38.1 mm
local display
Without
Product certifications
EAC
CE
RCM
cULus
Product or component type
Electronic pressure sensors
[uimp] rated impulse withstand voltage
0.5 kV
[us] rated supply voltage
12...24 V DC SELV (voltage limits: 7…33 V)
Analogue output function
4...20 mA, 2-wire
Current consumption
< 23 mA
diameter
26 mm
Quantity per set
Set of 1
Drift of the sensitivity
+/- 0.02 % of measuring range/°K
Drift of the zero point
+/- 0.02 % of measuring range/°K
pressure setting range
0…250 bar
Destruction pressure
1500 bar
Electrical circuit type
Control circuit
Net weight
0.094 kg
measurement accuracy
+/- 0.5 % of the measuring range
Operating position
Any position
mechanical durability
10000000 cycles
Materials in contact with fluid
Fluorocarbon FPM
Stainless steel AISI 316L
electrical connection
1 male connector M12 4 pins
Maximum permissible accidental pressure
750 bar
Resolution
0.1 % of the measuring range
Shock resistance
100 gn for 11 ms conforming to EN/IEC 60068-2-27
Response time on output
<= 2 ms 10...90 % of full scale
Type of output signal
Analogue
Protection type
Load short-circuit
Reverse polarity
Environment
Ambient air temp for storage/transportation
-50…100 °C
ip degree of protection
IP65 conforming to EN/IEC 60529
IP67 conforming to EN/IEC 60529
IP69K conforming to EN/IEC 60529
Range of product
Telemecanique Pressure sensors XM
ambient air temperature for operation
-30…85 °C
electromagnetic compatibility
Electrostatic discharge immunity test conforming to EN/IEC 61000-4-2 8 kV air, 4 kV contact
1.2/50 µs shock waves immunity test conforming to EN/IEC 61000-4-5 1 kV 42 Ohm
Immunity to magnetic fields conforming to EN/IEC 61000-4-8 100 A/m 50 Hz
Electrical fast transient/burst immunity test conforming to EN/IEC 61000-4-4 4 kV
Susceptibility to electromagnetic fields conforming to EN/IEC 61000-4-3 10 V/m 80...3000 MHz
Radiated RF fields conforming to EN/IEC 61000-4-6 10 V 0.01...80 MHz
standards
EN/IEC 61326-2-3
NSF ANSI 61
vibration resistance
20 gn (f = 15…2000 Hz) conforming to EN/IEC 60068-2-6
protective treatment
TC