SPECIFICATIONS
Main
Fluid connection type 1/4" - 18 NPT (male)
controlled fluid Fresh water (0…135 °C)
Air (-40…135 °C)
Hydraulic oil (-40…135 °C)
Gas (-40…135 °C)
Refrigeration fluid (-40…135 °C)
Type of packing Individual
pressure sensor name XMLP
pressure rating 1034.21 kPa
pressure sensor type Pressure transmitter
Complementary
length [l] 36 mm
local display Without
Product certifications CE
RCM
EAC
cULus
Product or component type Electronic pressure sensors
[uimp] rated impulse withstand voltage 0.5 kV
[us] rated supply voltage 24 V DC SELV (voltage limits: 12…33 V)
Analogue output function 0...10 V, 3-wire
Current consumption < 7 mA
diameter 26 mm
Quantity per set Set of 1
Drift of the sensitivity +/- 0.02 % of measuring range/°K
Drift of the zero point +/- 0.02 % of measuring range/°K
pressure setting range 0.00…1034.21 kPa
Destruction pressure 6205.28 kPa
Electrical circuit type Control circuit
Net weight 0.088 kg
measurement accuracy +/- 0.5 % of the measuring range
Operating position Any position
mechanical durability 10000000 cycles
Materials in contact with fluid Stainless steel AISI 316L
electrical connection 1 male connector M12 4 pins
Maximum permissible accidental pressure 3102.64 kPa
Resolution 0.1 % of the measuring range
Shock resistance 100 gn for 11 ms conforming to EN/IEC 60068-2-27
Response time on output <= 2 ms 10...90 % of full scale
Type of output signal Analogue
Protection type Reverse polarity
Load short-circuit
Environment
Ambient air temp for storage/transportation -50…100 °C
ip degree of protection IP65 conforming to EN/IEC 60529
IP67 conforming to EN/IEC 60529
IP69K conforming to EN/IEC 60529
Range of product Telemecanique Pressure sensors XM
ambient air temperature for operation -30…85 °C
electromagnetic compatibility Electrical fast transient/burst immunity test conforming to EN/IEC 61000-4-4 2 kV
Electrostatic discharge immunity test conforming to EN/IEC 61000-4-2 8 kV air, 4 kV contact
1.2/50 µs shock waves immunity test conforming to EN/IEC 61000-4-5 1 kV 42 Ohm
Immunity to magnetic fields conforming to EN/IEC 61000-4-8 100 A/m 50 Hz
Susceptibility to electromagnetic fields conforming to EN/IEC 61000-4-3 10 V/m 80...3000 MHz
Radiated RF fields conforming to EN/IEC 61000-4-6 10 V 0.01...80 MHz
standards NSF ANSI 61
EN/IEC 61326-2-3
vibration resistance 20 gn (f = 15…2000 Hz) conforming to EN/IEC 60068-2-6