Main
Device short name
XMLD
pressure actuator
Diaphragm
Fluid connection type
G 1/4 (female) conforming to ISO 228
product specific application
Dual stage
[ui] rated insulation voltage
300 V conforming to UL 508
500 V conforming to EN/IEC 60947-1
300 V conforming to CSA C22.2 No 14
controlled fluid
Air (0…160 °C)
Hydraulic oil (0…160 °C)
Pressure switch type of operation
Detection of 2 single thresholds
pressure rating
0.35 bar
pressure sensor type
Electromechanical pressure sensor
Complementary
[in] rated current
3 A, B300, AC-15 (Ue = 120 V) conforming to EN/IEC 60947-5-1
1.5 A, B300, AC-15 (Ue = 240 V) conforming to EN/IEC 60947-5-1
0.1 A, R300, DC-13 (Ue = 250 V) conforming to EN/IEC 60947-5-1
local display
Without
Product certifications
UL
CSA
EAC
Handle front plate colour
162 mm
Product or component type
Electromechanical pressure sensor
[uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-1
awg gauge
AWG 20...AWG 14
cable entry
Cable gland 7…13 mm
Enclosure material
Zinc alloy
Contacts type and composition
2 C/O snap action, silver contacts
2 C/O staggered, silver contacts
Electrical shock protection class
Class I conforming to IEC 1140
Class I conforming to IEC 536
Class I conforming to NF C 20-030
width (w)
110 mm
Destruction pressure
4.5 bar
Electrical circuit type
Control circuit
Net weight
2.575 kg
setting
External
Operating position
Any position
terminal block type
8 terminals
depth
110 mm
mechanical durability
4000000 cycles
repeat accuracy
2 %
Materials in contact with fluid
Steel
304L stainless steel
FPM, FKM
electrical connection
Screw-clamps terminals, 1 x 0.5...2 x 2.5 mm²
Maximum operating rate
120 cyc/mn
Maximum resistance across terminals
25 mOhm conforming to IEC 255-7 category 3
25 mOhm conforming to NF C 93-050 method A
Maximum permissible accidental pressure
2.25 bar
Maximum permissible pressure - per cycle
1.25 bar
Natural differential at high setting
0.03 bar
Natural differential at low setting
0.03 bar
Shock resistance
30 gn conforming to IEC 60068-2-27
Scale type
Fixed differential
Spread between 2 stages
0.025…0.31 bar
Short-circuit protection
10 A cartridge fuse, type gG (gl)
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP66 conforming to EN/IEC 60529
Range of product
OsiSense XM
ambient air temperature for operation
-25…70 °C
standards
EN/IEC 60947-5-1
CSA C22.2 No 14
CE
UL 508
vibration resistance
2 gn conforming to IEC 60068-2-6 (f = 30…500 Hz)
protective treatment
TC standard version