Main
Device short name
XMLC
pressure actuator
Diaphragm
Fluid connection type
G 1/4 (female) conforming to ISO 228
product specific application
-
[ui] rated insulation voltage
300 V conforming to UL 508
500 V conforming to EN/IEC 60947-1
300 V conforming to CSA C22.2 No 14
controlled fluid
Air (0…70 °C)
Fresh water (0…70 °C)
Hydraulic oil (0…70 °C)
Pressure switch type of operation
Regulation between 2 thresholds
pressure rating
5 bar
pressure sensor type
Electromechanical vacuum-pressure sensor
Complementary
[in] rated current
3 A, B300, AC-15 (Ue = 120 V) conforming to EN/IEC 60947-5-1
1.5 A, B300, AC-15 (Ue = 240 V) conforming to EN/IEC 60947-5-1
0.1 A, R300, DC-13 (Ue = 250 V) conforming to EN/IEC 60947-5-1
local display
With
Product certifications
EAC
UL
CSA
Adjustable range of switching point on falling pressure
-1…4.55 bar
Auxiliary contacts operation
Simultaneous, snap action
Handle front plate colour
113 mm
Product or component type
Electromechanical pressure sensor
[uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-1
Adjustable range of switching point on rising pressure
-0.55…5 bar
awg gauge
AWG 20...AWG 14
cable entry
Cable gland 9…13 mm
Contacts material
Silver contacts
Enclosure material
Zinc alloy
Contacts type and composition
2 C/O
Electrical shock protection class
Class I conforming to IEC 1140
Class I conforming to IEC 536
Class I conforming to NF C 20-030
width (w)
46 mm
Destruction pressure
23 bar
Electrical circuit type
Control circuit
Net weight
0.685 kg
setting
External
Operating position
Any position
terminal block type
8 terminals
depth
85 mm
mechanical durability
3000000 cycles
repeat accuracy
2 %
Materials in contact with fluid
Zinc alloy
Nitrile
304L stainless steel
electrical connection
Screw-clamps terminals, 1 x 0.5...2 x 2.5 mm²
Maximum operating rate
120 cyc/mn
Maximum resistance across terminals
25 mOhm conforming to IEC 255-7 category 3
25 mOhm conforming to NF C 93-050 method A
Maximum permissible accidental pressure
11.25 bar
Maximum permissible pressure - per cycle
6.25 bar
Possible differential maximum at high setting
6 bar
Possible differential minimum at high setting
0.45 bar (+/- 0.1 bar)
Possible differential minimum at low setting
0.45 bar (+/- 0.1 bar)
Shock resistance
50 gn conforming to IEC 60068-2-27
Scale type
Adjustable differential
Short-circuit protection
10 A cartridge fuse, type gG (gl)
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP66 conforming to EN/IEC 60529
Range of product
OsiSense XM
ambient air temperature for operation
-25…70 °C
standards
IEC 60947-5-1
CE
EN/IEC 60947-5-1
CSA C22.2 No 14
EN 60947-5-1
UL 508
vibration resistance
4 gn conforming to IEC 60068-2-6 (f = 30…500 Hz)
protective treatment
TC standard version