Main
Device short name
XMLA
pressure actuator
Piston
Fluid connection type
G 1/4 (female) conforming to ISO 228
product specific application
-
[ui] rated insulation voltage
300 V conforming to UL 508
500 V conforming to EN/IEC 60947-1
300 V conforming to CSA C22.2 No 14
controlled fluid
Air (0…160 °C)
Corrosive fluid (0…160 °C)
Pressure switch type of operation
Detection of 1 single threshold
pressure rating
500 bar
pressure sensor type
Electromechanical pressure sensor
Complementary
[in] rated current
3 A, B300, AC-15 (Ue = 120 V) conforming to EN/IEC 60947-5-1
1.5 A, B300, AC-15 (Ue = 240 V) conforming to EN/IEC 60947-5-1
0.1 A, R300, DC-13 (Ue = 250 V) conforming to EN/IEC 60947-5-1
local display
With
Product certifications
UL
CSA
BV
LROS (Lloyds register of shipping)
CCC
EAC
Adjustable range of switching point on falling pressure
10…455 bar
Auxiliary contacts operation
Snap action
Handle front plate colour
113 mm
Product or component type
Electromechanical pressure sensor
[uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-1
Adjustable range of switching point on rising pressure
30…500 bar
Contacts material
Silver contacts
Enclosure material
Zinc alloy
Contacts type and composition
1 C/O
Electrical shock protection class
Class I conforming to IEC 1140
Class I conforming to IEC 536
Class I conforming to NF C 20-030
width (w)
35 mm
Destruction pressure
2250 bar
Electrical circuit type
Control circuit
Net weight
0.78 kg
setting
External
Operating position
Any position
terminal block type
4 terminals
depth
75 mm
mechanical durability
3000000 cycles
repeat accuracy
2 %
Materials in contact with fluid
316L stainless steel
FPM, FKM
PTFE
electrical connection
1 male connector EN 175301-803-A (ex DIN43650), 4 pins
Maximum operating rate
60 cyc/mn
Maximum resistance across terminals
25 mOhm conforming to IEC 255-7 category 3
25 mOhm conforming to NF C 93-050 method A
Maximum permissible accidental pressure
1125 bar
Maximum permissible pressure - per cycle
625 bar
Natural differential at high setting
45 bar (+/- 10 bar)
Natural differential at low setting
20 bar (+/- 6 bar)
Shock resistance
50 gn conforming to IEC 60068-2-27
Scale type
Fixed differential
Short-circuit protection
10 A cartridge fuse, type gG (gl)
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP65 conforming to EN/IEC 60529
Range of product
Telemecanique Pressure sensors XM
ambient air temperature for operation
-25…70 °C
standards
CSA C22.2 No 14
EN/IEC 60947-5-1
CE
UL 508
vibration resistance
4 gn conforming to IEC 60068-2-6 (f = 30…500 Hz)
protective treatment
TC standard version