Main
																					
												Device short name
												XMLA
											
                            
																					
												pressure actuator
												Diaphragm
											
                            
																					
												Fluid connection type
												G 1/4 (female) conforming to ISO 228
											
                            
																					
												product specific application
												-
											
                            
																					
												[ui] rated insulation voltage
												300 V conforming to UL 508
500 V conforming to EN/IEC 60947-1
300 V conforming to CSA C22.2 No 14
											
                            
																					
												controlled fluid
												Air (0…160 °C)
Fresh water (0…160 °C)
Hydraulic oil (0…160 °C)
											
                            
																					
												Pressure switch type of operation
												Detection of 1 single threshold
											
                            
																					
												pressure rating
												20 bar
											
                            
																					
												pressure sensor type
												Electromechanical pressure sensor
											
                            
																			 
																	
										Complementary
																					
												[in] rated current
												3 A, B300, AC-15 (Ue = 120 V) conforming to EN/IEC 60947-5-1
1.5 A, B300, AC-15 (Ue = 240 V) conforming to EN/IEC 60947-5-1
0.1 A, R300, DC-13 (Ue = 250 V) conforming to EN/IEC 60947-5-1
											
                            
																					
												local display
												With
											
                            
																					
												Product certifications
												CCC
EAC
LROS (Lloyds register of shipping)
CSA
UL
BV
											
                            
																					
												Adjustable range of switching point on falling pressure
												0.6…19 bar
											
                            
																					
												Auxiliary contacts operation
												Snap action
											
                            
																					
												Handle front plate colour
												113 mm
											
                            
																					
												Product or component type
												Electromechanical pressure sensor
											
                            
																					
												[uimp] rated impulse withstand voltage
												6 kV conforming to EN/IEC 60947-1
											
                            
																					
												Adjustable range of switching point on rising pressure
												1…20 bar
											
                            
																					
												Contacts material
												Silver contacts
											
                            
																					
												Enclosure material
												Zinc alloy
											
                            
																					
												Contacts type and composition
												1 C/O
											
                            
																					
												Electrical shock protection class
												Class I conforming to IEC 1140
Class I conforming to IEC 536
Class I conforming to NF C 20-030
											
                            
																					
												width (w)
												35 mm
											
                            
																					
												Destruction pressure
												90 bar
											
                            
																					
												Electrical circuit type
												Control circuit
											
                            
																					
												Net weight
												0.715 kg
											
                            
																					
												setting
												External
											
                            
																					
												Operating position
												Any position
											
                            
																					
												terminal block type
												4 terminals
											
                            
																					
												depth
												75 mm
											
                            
																					
												mechanical durability
												5000000 cycles
											
                            
																					
												repeat accuracy
												2 %
											
                            
																					
												Materials in contact with fluid
												Brass
FPM, FKM
											
                            
																					
												electrical connection
												1 male connector EN 175301-803-A (ex DIN43650), 4 pins
											
                            
																					
												Maximum operating rate
												120 cyc/mn
											
                            
																					
												Maximum resistance across terminals
												25 mOhm conforming to IEC 255-7 category 3
25 mOhm conforming to NF C 93-050 method A
											
                            
																					
												Maximum permissible accidental pressure
												45 bar
											
                            
																					
												Maximum permissible pressure - per cycle
												25 bar
											
                            
																					
												Natural differential at high setting
												1 bar (+/- 0.1 bar)
											
                            
																					
												Natural differential at low setting
												0.4 bar (+/- 0.2 bar)
											
                            
																					
												Shock resistance
												50 gn conforming to IEC 60068-2-27
											
                            
																					
												Scale type
												Fixed differential
											
                            
																					
												Short-circuit protection
												10 A cartridge fuse, type gG (gl)
											
                            
																			 
																	
										Environment
																					
												Ambient air temp for storage/transportation
												-40…70 °C
											
                            
																					
												ip degree of protection
												IP65 conforming to EN/IEC 60529
											
                            
																					
												Range of product
												OsiSense XM
											
                            
																					
												ambient air temperature for operation
												-25…70 °C
											
                            
																					
												standards
												EN/IEC 60947-5-1
CSA C22.2 No 14
UL 508
CE
											
                            
																					
												vibration resistance
												4 gn conforming to IEC 60068-2-6 (f = 30…500 Hz)
											
                            
																					
												protective treatment
												TC standard version