Main
Device short name
XF9
[ithe] thermal current under enclosure
200 A at -25…40 °C 3-pole scheme
product specific application
Safety of hoisting equipment
[ui] rated insulation voltage
660 V conforming to IEC 158-1
660 V conforming to IEC 947-4
660 V conforming to VDE 0110 group C
600 V conforming to CSA C22.2 No 14
reset
Manual reset
Complementary
[ie] rated operational current
AC-3, Ie = 115 A 3-pole scheme
[ics] rated service breaking capacity
1100 kA at 500 V 2-pole scheme conforming to IEC 158-1
900 kA at 660 V 2-pole scheme conforming to IEC 158-1
Cable cross section
1 solid cable 95 mm² with cable end
2 solid cable 95 mm² with cable end
Product certifications
CSA
Product or component type
Overtravel limit switches
cable entry
2 entries tapped for Pg 36 cable gland
contact operation
Snap action
Contacts type and composition
Without auxiliary contact block
Material
Sheet steel: enclosure
Type of operator
Manual latching
Electrical circuit type
Power circuit
Net weight
26 kg
Switch actuation
Horizontal and vertical approach
Poles description
3
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP43 conforming to EN/IEC 60529
Range of product
XR and XF
ambient air temperature for operation
-25…70 °C
standards
VDE 0660
IEC 158-1
NF C 63-110
IEC 947-4
IEC 947-1
protective treatment
TC