Main
Device short name
XF9
[ithe] thermal current under enclosure
160 A at -25…40 °C 2-pole scheme
80 A at -25…40 °C 3-pole scheme
product specific application
Safety of hoisting equipment
[ui] rated insulation voltage
500 V conforming to IEC 158-1
500 V conforming to IEC 947-4
500 V conforming to VDE 0110 group C
600 V conforming to CSA C22.2 No 14
reset
Manual reset
Complementary
[ie] rated operational current
, Ie = 130 A 2-pole scheme
AC-3, Ie = 65 A 3-pole scheme
[ics] rated service breaking capacity
1000 kA at 500 V 2-pole scheme conforming to IEC 158-1
630 kA at 660 V 2-pole scheme conforming to IEC 158-1
Cable cross section
1 flexible cable 2.5…16 mm² with cable end
1 flexible cable 2.5…25 mm² without cable end
1 solid cable 2.5…25 mm² without cable end
2 flexible cable 2.5…16 mm² without cable end
2 flexible cable 2.5…6 mm² with cable end
2 solid cable 4…16 mm² without cable end
Product certifications
CSA
Product or component type
Overtravel limit switches
cable entry
3 entries tapped for Pg 29 cable gland
contact operation
Snap action
Contacts type and composition
Without auxiliary contact block
Material
Aluminium alloy: case
Type of operator
Manual latching, restricted by a padlockable device
Electrical circuit type
Power circuit
Net weight
3.83 kg
Maximum displacement angle
75 °
Switch actuation
Horizontal approach
Poles description
4
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP54 conforming to EN/IEC 60529
Range of product
XR and XF
ambient air temperature for operation
-25…70 °C
standards
VDE 0660
IEC 947-4
IEC 947-1
IEC 158-1
NF C 63-110
protective treatment
TC