Main
Device short name
XESP
[ui] rated insulation voltage
500 V conforming to IEC 60947-5-1
300 V conforming to CSA C22.2 No 14
Series name
Standard format
Complementary
product compatibility
XC2J
Associated body
ZC2JC26
ZC2JC2
Product or component type
Limit switch contact block
Contacts insulation form
Za
Contacts material
Silver plated contacts
contact operation
Snap action, simultaneous
Contacts type and composition
2 C/O
contact code designation
A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A
electrical durability
5000000 cycles, DC-13 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Positive opening
Without
electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.75...2 x 1.5 mm²
Maximum resistance across terminals
25 mOhm conforming to IEC 60255-7 category 3
Minimum actuation speed
0.01 mm/s
Poles description
2
Short-circuit protection
10 A cartridge fuse, type gG
Environment
Range of product
Telemecanique Limit switches XC Standard