All categories
Compare Cart

XESD1291 - Harmony XAC, Double contact block, spring return, 2speed, snap action, 2 NO + 1 C/O - Schneider Electric

Expected in 2-4 weeks
XESD1291 - Harmony XAC, Double contact block, spring return, 2speed, snap action, 2 NO + 1 C/O - Schneider Electric - Harmony XAC, Double contact block, spring return, 2speed, snap action, 2 NO + 1 C/O - Schneider Electric - 0
XESD1291 - Harmony XAC, Double contact block, spring return, 2speed, snap action, 2 NO + 1 C/O - Schneider Electric
112,86 €
112,86 € incl. VAT
Text About:
Harmony XAC, Double contact block, spring return, 2speed, snap action, 2 NO + 1 C/O - Schneider Electric
112,86 €
SPECIFICATIONS
Main
[ithe] thermal current under enclosure 12 A
contact block application 2-speed
[ui] rated insulation voltage 600 V conforming to CSA
component name XESD
contact block type Double
Complementary
product compatibility XACB
Product or component type Contact block
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1
Connections - terminals Screw clamp terminals, 1 x 2.5 mm² with or without cable end
Screw clamp terminals, 2 x 1.5 mm² with or without cable end
contact operation Snap action
Staggered
Contacts type and composition 2 NO + 1 C/O
Electrical shock protection class Class II conforming to IEC 61140
rated operational power in w 2200 W AC-3 at 240 V conforming to IEC 60947-3 appendix A
2200 W AC-4 at 400 V conforming to IEC 60947-3 appendix A
Horizontal fixing centres 40 mm
Type of operator 2 spring return
Electrical circuit type Power circuit
Mounting of block Front mounting
Net weight 0.19 kg
rated power in hp 2 hp at 240 V, CSA certified
3 hp at 600 V, CSA certified
5 hp at 400 V, CSA certified
mechanical durability 500000 cycles
1000000 cycles
electrical durability 300000 cycles AC-3, 2200 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
300000 cycles AC-3, 2200 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
300000 cycles AC-4, 2200 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
300000 cycles AC-4, 2200 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
500000 cycles AC-3, 1500 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
500000 cycles AC-4, 1500 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
800000 cycles AC-3, 1500 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
800000 cycles AC-4, 1500 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
Mechanical interlocking With mechanical interlocking
Operating force 17 N
Shock resistance 100 gn conforming to IEC 60068-2-27
Terminal identifier (13-14)NON !@ !(11-12)NC
Poles description 2-pole
Terminals description iso n°2 B
(43-44)NO
(61-62-64)OC
(33-34)NO
Short-circuit protection 10 A fuse protection by cartridge fuse type aM
Terminals description iso n°1 (13-14)NON
B
(23-24)NON
(51-52-54)OC
Environment
Ambient air temp for storage/transportation -40…70 °C
Range of product Harmony XAC
ambient air temperature for operation -25…70 °C
standards IEC 60947-3
CSA C22.2 No 14
EN 60947-3
vibration resistance 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
Recently viewed
112,86 €
112,86 € incl. VAT
Expected in 2-4 weeks