SPECIFICATIONS
Main
[ithe] thermal current under enclosure 12 A
contact block application Single speed
[ui] rated insulation voltage 600 V conforming to CSA
component name XESD
contact block type Double
Complementary
product compatibility XACB
Product or component type Contact block
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1
Connections - terminals Screw clamp terminals, 1 x 2.5 mm² with or without cable end
Screw clamp terminals, 2 x 1.5 mm² with or without cable end
contact operation Snap action
Contacts type and composition 2 NO
Electrical shock protection class Class II conforming to IEC 61140
rated operational power in w 2200 W AC-3 at 240 V conforming to IEC 60947-3 appendix A
2200 W AC-4 at 400 V conforming to IEC 60947-3 appendix A
Horizontal fixing centres 40 mm
Type of operator 2 spring return
Electrical circuit type Power circuit
Mounting of block Front mounting
rated power in hp 2 hp at 240 V, CSA certified
3 hp at 600 V, CSA certified
5 hp at 400 V, CSA certified
mechanical durability 500000 cycles
1000000 cycles
electrical durability 300000 cycles AC-3, 2200 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
300000 cycles AC-3, 2200 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
300000 cycles AC-4, 2200 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
300000 cycles AC-4, 2200 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
500000 cycles AC-3, 1500 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
500000 cycles AC-4, 1500 W at 240 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
800000 cycles AC-3, 1500 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
800000 cycles AC-4, 1500 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
Mechanical interlocking With mechanical interlocking
Operating force 17 N
Shock resistance 100 gn conforming to IEC 60068-2-27
Terminal identifier (11-12)NC
(13-14)NON
Poles description 2-pole
Terminals description iso n°2 (43-44)NO
(33-34)NO
B
Short-circuit protection 10 A fuse protection by cartridge fuse type aM
Terminals description iso n°1 (23-24)NON 
(13-14)NON 
B
Environment
Ambient air temp for storage/transportation -40…70 °C
Range of product Harmony XAC
ambient air temperature for operation -25…70 °C
standards EN 60947-3
CSA C22.2 No 14
IEC 60947-3
vibration resistance 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6