SPECIFICATIONS
Main
[ithe] thermal current under enclosure 10 A
contact block application Single speed
[ui] rated insulation voltage 500 V (pollution degree 3) conforming to IEC 60947-1
component name XESD
contact block type Double
Complementary
product compatibility XACB
XACM
Product or component type Contact block
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1
Connections - terminals Screw clamp terminals, 1 x 2.5 mm² with or without cable end
Screw clamp terminals, 2 x 1.5 mm² with or without cable end
contact operation Snap action
Electrical shock protection class Class II conforming to IEC 61140
rated operational power in w 140 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
140 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
95 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
Type of operator 2 spring return
Electrical circuit type Control circuit
rated operational power in va 100 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load)
450 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load)
50 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load)
750 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load)
contact code designation A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A
Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
Mounting of block Front mounting
mechanical durability 1000000 cycles
Maximum resistance across terminals 25 MOhm
Mechanical interlocking With mechanical interlocking
Operating force 15 N
25 N
Shock resistance 100 gn conforming to IEC 60068-2-27
Terminal identifier (13-14)NON !@ !(11-12)NC
Terminals description iso n°2 B
(23-24-21-22)OF
Short-circuit protection 10 A fuse protection by cartridge fuse type gG
Terminals description iso n°1 B
(13-14-11-12)OF
Environment
Ambient air temp for storage/transportation -40…70 °C
Range of product Harmony XAC
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 14
EN 60947-5-1
IEC 60947-5-1
vibration resistance 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6