Main
Device short name
XEP3
Series name
Special format
head type
Plunger head
Complementary
detector design
Miniature, DIN 41635 A format
[ith] conventional thermal current
5 A at 250 V 50/60 Hz
Handle front plate colour
16 mm
Product or component type
Microswitch
marking
CE
Contacts material
AgNi
contact operation
Snap action
Contacts type and composition
1 C/O very low force
body material
Polyester
width (w)
10 mm
Type of operator
Plunger
contact code designation
B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN/IEC 60947-5-1 appendix A
D300, AC-15 (Ue = 240 V, Ie = 0.3 A) conforming to EN/IEC 60947-5-1 appendix A
Net weight
5.6 g
Inter contact distance
0.4 mm
depth
28 mm
mechanical durability
50000000 cycles
Maximum differential travel
0.35 mm lever fixing position in A
0.35 mm lever fixing position in B
0.35 mm lever fixing position in C
Maximum force for tripping
0.25 N lever fixing position in A
0.25 N lever fixing position in B
0.25 N lever fixing position in C
electrical connection
6.35 mm cable clip tags
Maximum permissible end of travel force
20 N lever fixing position in A
20 N lever fixing position in B
20 N lever fixing position in C
Minimum over travel
1.1 mm lever fixing position in A
1.1 mm lever fixing position in B
1.1 mm lever fixing position in C
Minimum release force
0.05 N lever fixing position in A
0.05 N lever fixing position in B
0.05 N lever fixing position in C
Movement of operating head
Linear
Switch actuation
On end
Tripping point
14.7 mm lever fixing position in A
14.7 mm lever fixing position in B
14.7 mm lever fixing position in C
Type of approach
Vertical approach
Terminals description iso n°1
(1-2-4)OC
Environment
ip degree of protection
IP40
Range of product
OsiSense XC
ambient air temperature for operation
-25…125 °C
standards
IEC 60947-5-1
UL 1054
CURus
EN 60947-5-1
EN 61058