Main
[ithe] thermal current under enclosure
10 A
contact block application
Emergency stop push-button
[ui] rated insulation voltage
400 V (pollution degree 3) conforming to IEC 60947-1
component name
XENT
contact block type
Single
Complementary
product compatibility
XACB
Product or component type
Contact block
[uimp] rated impulse withstand voltage
4 kV conforming to IEC 60947-1
Connections - terminals
Screw clamp terminals, 1 x 2.5 mm² with or without cable end
Screw clamp terminals, 2 x 1.5 mm² with or without cable end
contact operation
Slow-break
Contacts type and composition
3 NC
rated operational power in w
3000 W AC-23B at 400 V
Type of operator
Spring return
Electrical circuit type
Control circuit
Power circuit
Net weight
0.04 kg
mechanical durability
3000000 cycles
Shock resistance
70 gn conforming to IEC 60068-2-27
Short-circuit protection
6 A fuse protection by cartridge fuse type aM
Terminals description iso n°1
(31-32)NC
(11-12)NC
(21-22)NC
Environment
Ambient air temp for storage/transportation
-40…70 °C
Range of product
Harmony XAC
ambient air temperature for operation
-25…70 °C
overvoltage category
Class II conforming to IEC 61140
standards
CSA C22.2 No 14
EN/IEC 60947-5-1
UL 508
vibration resistance
15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6