All categories
Compare Cart

XENT1192 - Isolating switch, Harmony XAC, single block XEN T, for control circuit - Schneider Electric

Expected in 2-4 weeks
XENT1192 - Isolating switch, Harmony XAC, single block XEN T, for control circuit - Schneider Electric - Isolating switch, Harmony XAC, single block XEN T, for control circuit - Schneider Electric - 0
XENT1192 - Isolating switch, Harmony XAC, single block XEN T, for control circuit - Schneider Electric
43,69 € excl. VAT
53,30 € incl. VAT
Text About:
Isolating switch, Harmony XAC, single block XEN T, for control circuit - Schneider Electric
53,30 €
SPECIFICATIONS
Main
[ithe] thermal current under enclosure 10 A
contact block application Emergency stop push-button
[ui] rated insulation voltage 400 V (pollution degree 3) conforming to IEC 60947-1
component name XENT
contact block type Single
Complementary
product compatibility XACA
Product or component type Isolating switch
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1
Connections - terminals Screw clamp terminals, 1 x 0.5...1 x 2.5 mm² without cable end
Screw clamp terminals, 1 x 0.5...2 x 1.5 mm² with cable end
contact operation Slow-break
Contacts type and composition 3 NC
Electrical shock protection class Class II conforming to IEC 61140
rated operational power in w 40 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
65 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
Electrical circuit type Control circuit
contact code designation A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A
A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A
Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A
Mounting of block Front mounting
Net weight 0.05 kg
mechanical durability 1000000 cycles
Maximum resistance across terminals 25 MOhm
Operating force 14 N
Shock resistance 100 gn conforming to IEC 60068-2-27
Short-circuit protection 10 A fuse protection by cartridge fuse type gG
Environment
Ambient air temp for storage/transportation -40…70 °C
Range of product Harmony XAC
ambient air temperature for operation -25…70 °C
standards CSA C22.2 No 14
UL 508
EN/IEC 60947-5-1
EN/IEC 60204-32
vibration resistance 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
Recently viewed
43,69 € excl. VAT
53,30 € incl. VAT
Expected in 2-4 weeks