All categories
Compare Cart

XENG1191 - Single contact block, Harmony XAC, spring return, 2 speed, spring return, front mounting, 2NO+1NC - Schneider Electric

Expected in 2-4 weeks EAN: 3389110645705
XENG1191 - Single contact block, Harmony XAC, spring return, 2 speed, spring return, front mounting, 2NO+1NC - Schneider Electric - Single contact block, Harmony XAC, spring return, 2 speed, spring return, front mounting, 2NO+1NC - Schneider Electric - 0
XENG1191 - Single contact block, Harmony XAC, spring return, 2 speed, spring return, front mounting, 2NO+1NC - Schneider Electric - Single contact block, Harmony XAC, spring return, 2 speed, spring return, front mounting, 2NO+1NC - Schneider Electric - 1
XENG1191 - Single contact block, Harmony XAC, spring return, 2 speed, spring return, front mounting, 2NO+1NC - Schneider Electric - Single contact block, Harmony XAC, spring return, 2 speed, spring return, front mounting, 2NO+1NC - Schneider Electric - 2
XENG1191 - Single contact block, Harmony XAC, spring return, 2 speed, spring return, front mounting, 2NO+1NC - Schneider Electric - Single contact block, Harmony XAC, spring return, 2 speed, spring return, front mounting, 2NO+1NC - Schneider Electric - 3
XENG1191 - Single contact block, Harmony XAC, spring return, 2 speed, spring return, front mounting, 2NO+1NC - Schneider Electric - Single contact block, Harmony XAC, spring return, 2 speed, spring return, front mounting, 2NO+1NC - Schneider Electric - 4
EAN: 3389110645705
XENG1191 - Single contact block, Harmony XAC, spring return, 2 speed, spring return, front mounting, 2NO+1NC - Schneider Electric
13,56 €
13,56 € incl. VAT
Text About:
Single contact block, Harmony XAC, spring return, 2 speed, spring return, front mounting, 2NO+1NC - Schneider Electric
13,56 €
SPECIFICATIONS
Main
product range Harmony XAC
[ithe] thermal current under enclosure 10 A
contact block application 2 vitesses
type of product or equipment Bloc de contacts
[ui] rated insulation voltage 600 V (degré de pollution 3) se conformer à CEI 60947-1
type of electrical circuit Télécommande
component name XENG
contact block type Unique
Complementary
associated accessories XACA
XACA9…tête
contact description 1 "O" + 2 "F"
assembly of the block Montage avant
[uimp] rated impulse withstand voltage 6 kV se conformer à CEI 60947-1
actuation effort 18 N
product weight 0,04 kg
description of iso n°1 terminals (21-22)NC
(33-34)NON_CL
(13-14)NON
connection mode Borniers à vis-étrier, 1 x 0,5…1 x 2,5 mm² sans embout
Borniers à vis-étrier, 1 x 0,5…2 x 1,5 mm² avec embout
contact operation À action dépendante
Échelonné
mechanical endurance 1000000 cycle
rated operational power in w 40 W DC-13 pour 1000000 cycle, cadence de fonctionnement <60 cyc/mn à 120 V, facteur de charge = 0,5 (inductive charge) se conformer à CEI 60947-5-1 appendix C
48 W DC-13 pour 1000000 cycle, cadence de fonctionnement <60 cyc/mn à 48 V, facteur de charge = 0,5 (inductive charge) se conformer à CEI 60947-5-1 appendix C
65 W DC-13 pour 1000000 cycle, cadence de fonctionnement <60 cyc/mn à 24 V, facteur de charge = 0,5 (inductive charge) se conformer à CEI 60947-5-1 appendix C
contact code designation A600 AC-15, Ue = 240 V, Ie = 3 A se conformer à CEI 60947-5-1 appendix A
A600 AC-15, Ue = 600 V, Ie = 1,2 A se conformer à CEI 60947-5-1 appendix A
Q600 DC-13, Ue = 250 V, Ie = 0,27 A se conformer à CEI 60947-5-1 appendix A
Q600 DC-13, Ue = 600 V, Ie = 0,1 A se conformer à CEI 60947-5-1 appendix A
order type Rappel à ressort
maximum resistance between terminals 25 MΩ
short circuit protection 10 A fusible de protection par cartouche fusible type gG
Environment
overvoltage category Classe II se conformer à CEI 61140
standards UL 508
EN/CEI 60947-5-1
CSA C22.2 No 14
operating ambient air temperature -25…70 °C
storage room temperature -40…70 °C
mechanical shock resistance 100 gn se conformer à CEI 60068-2-27
vibration resistance 15 gn (f= 10…500 Hz) se conformer à CEI 60068-2-6
Recently viewed
13,56 €
13,56 € incl. VAT
Expected in 2-4 weeks