Main
Control station name
XACB
XACM
[ithe] thermal current under enclosure
6 A
[ui] rated insulation voltage
250 V (pollution degree 3) conforming to IEC 60947-1
control circuit type
DC
Complementary
Product or component type
Non booted push-button
[us] rated supply voltage
0...15 V
Current consumption
< 15 mA
Connections - terminals
Terminal connectors, 1 x 2.5 mm²
Terminal connectors, 2 x 1.5 mm²
rated power in va
30 VA AC-15 for 1000000 cycles at 110 V 50/60 Hz conforming to IEC 60947-5-1 appendix C
30 VA AC-15 for 1000000 cycles at 230 V 50/60 Hz conforming to IEC 60947-5-1 appendix C
30 VA AC-15 for 1000000 cycles at 48 V 50/60 Hz conforming to IEC 60947-5-1 appendix C
Contacts type and composition
1 NC + 1 NO at start of travel
1 NO at end of travel
Operating travel
11 mm
Electrical circuit type
Control circuit
Net weight
0.065 kg
mechanical durability
1000000 cycles
Operating force
4 N at start of travel
9 N at end of travel
Rated power in w
DC-13: 12 W 110 V inductive conforming to IEC 60947-5-1 appendix C 1000000 cycles
DC-13: 48 W 48 V inductive conforming to IEC 60947-5-1 appendix C 1000000 cycles
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP65 conforming to IEC 60529
Range of product
Harmony XAC
ambient air temperature for operation
-25…70 °C
standards
IEC 60947-5-1
EN 60947-5-1