Complementary
Product certifications
BG
UL
CSA
Handle front plate colour
117 mm
Product or component type
Guard switch
[uimp] rated impulse withstand voltage
4 kV conforming to EN/IEC 60947-5-1
cable entry
2 entries tapped for M16 x 1.5
cable outer diameter
7…10 mm
Enclosure material
Polyamide PA66 fibre glass impregnated
Clamping connection capacity
1 x 0.34...2 x 0.75 mm² with or without cable end
contact operation
Slow-break
Contacts type and composition
1 NC + 1 NC + 1 NC
Electrical shock protection class
Class II conforming to EN/IEC 61140
safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Material
Plastic
width (w)
52 mm
Type of operator
Spindle 80 mm
contact code designation
B300, AC-15 (Ue = 120 V, Ie = 6 A) conforming to EN/IEC 60947-5-1
B300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1
Q300, DC-13 (Ue = 125 V, Ie = 0.2 A) conforming to EN/IEC 60947-5-1
R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN/IEC 60947-5-1
Net weight
0.187 kg
Lever material
Stainless steel
depth
110 mm
mechanical durability
1000000 cycles
Positive opening
With NC contact
electrical connection
Terminal
Maximum resistance across terminals
30 mOhm conforming to EN/IEC 60947-5-4
Minimum actuation speed
0.1 m/s
Minimum torque for tripping
0.1 N.m
Insulation
Double insulated
Positive opening minimum torque
0.45 N.m
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Poles description
3
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Short-circuit protection
6 A cartridge fuse type gG (gl)
Tripping angle
5 °
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP67 conforming to IEC 60529
Range of product
Telemecanique Safety switches XCS
ambient air temperature for operation
-25…70 °C
standards
EN/ISO 12100
CSA C22.2 No 14
EN/IEC 60947-5-1
UL 508
EN 1088/ISO 14119
EN/IEC 60204-1
EN/IEC 60947-5-4
vibration resistance
50 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TH
TC