Complementary
[ie] rated operational current
0.55 A at 125 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
3 A at 120 V, AC-15, B300 conforming to EN/IEC 60947-5-1
1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1
[un] rated nominal voltage
24 V - 20...10 %
Product certifications
UL
CSA
Handle front plate colour
94 mm
Product or component type
Safety switch
[uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-5-1
Actuator forcible withdrawal rtc
500 N
Load factor
1
cable entry
1 entry tapped for M16 x 1.5
Locking options description
With interlocking, locking by solenoid
cable outer diameter
7…10 mm
contact operation
Slow-break, simultaneous
Contacts type and composition
2 NC
Electrical shock protection class
Class II conforming to EN/IEC 61140
safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
body material
PA (polyamide)
Material
Plastic
width (w)
110 mm
Net weight
0.36 kg
head material
PA (polyamide)
depth
33 mm
Electromagnet interlocking
Locking on de-energisation and unlocking on energisation of solenoid
mechanical durability
1000000 cycles
Maximum actuation speed
0.5 m/s
Positive opening
With NC contact
Power consumption in va
10 VA
electrical connection
Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Maximum operating rate
10 cyc/mn for maximum durability
Minimum actuation speed
0.01 m/s
Insulation
Double insulated
Positive opening minimum force
15 N
Shock resistance
10 gn for 11 ms conforming to IEC 60068-2-27
Poles description
2
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Supply frequency
50/60 Hz
Short-circuit protection
10 A cartridge fuse type gG (gl)
Supply voltage type
AC/DC
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Range of product
Telemecanique Safety switches XCS
ambient air temperature for operation
-25…60 °C
standards
EN/ISO 12100
EN/IEC 60947-5-1
UL 508
EN/IEC 60204-1
CSA C22.2 No 14
EN 1088/ISO 14119
vibration resistance
5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TC