Main
design
Rectangular, standard
[ui] rated insulation voltage
30 V DC
approach directions
3 directions-transponder with rotary sensing face
component name
XCSRC
Complementary
[ie] rated operational current
60 mA
[ue] rated operational voltage
24 V DC (- 20...10 %)SELV or PELV conforming to EN/IEC 60204-1
[sao] assured operating sensing distance
10 mm face to face
Product certifications
IC
RCM
Ecolab
TÜV
CSA 22-2
E2
EAC
FCC
response time
250 ms typical
[sar] trigger distance
35 mm face to face
Product or component type
Preventa RFID safety switch
tightening torque
< 1.5 N.m
[uimp] rated impulse withstand voltage
0.8 kV conforming to IEC 60947-5-2
marking
RCM
IC
EAC
FCC
TÜV
CULus
CE
Electrical shock protection class
Class III conforming to EN/IEC 61140
safety reliability data
PFH
D
= 5E-10/h conforming to EN/IEC 62061
PFH
D
= 5E-10/h conforming to EN/ISO 13849-1
Material
Valox
switching frequency
<= 0.5 Hz
Local signalling
Green, orange and red 2 multi-colour LEDs
Maximum delay first up
5 s
switching capacity in ma
400 mA
connector type
M12 male
Mission time
20 year(s)
electrical connection
1 male connector
Maximum switching voltage
26.4 V DC
Risk time
120 ms
Safety outputs
2 NO
Shock resistance
30 gn for 11 ms conforming to EN/IEC 60068-2-27
Poles description
8
Safety level
SIL 3 conforming to EN/IEC 61508
SILCL 3 conforming to EN/IEC 62061
PL = e conforming to EN/ISO 13849-1
Category 4 conforming to EN/ISO 13849-1
Type of output stage
Solid-state, PNP
Size
Transponder: 50 x 15 x 15 mm
Reader: 108.3 x 30 x 15 mm
Protection type
Short-circuit protection
Environment
Ambient air temp for storage/transportation
-40…85 °C
ip degree of protection
IP65 conforming to EN/IEC 60529
IP66 conforming to EN/IEC 60529
IP67 conforming to EN/IEC 60529
IP69K conforming to DIN 40050
Range of product
Telemecanique Safety switches XCS
ambient air temperature for operation
-25…70 °C
standards
EN/IEC 60947-5-3
ISO 14119
EN/IEC 60947-5-2
vibration resistance
10 gn (f= 10…150 Hz) conforming to EN/IEC 60068-2-6