[ithe] thermal current under enclosure
10 A
[ui] rated insulation voltage
300 V conforming to UL 508
300 V conforming to CSA C22.2 No 14
500 V (pollution degree 3) conforming to EN/IEC 60947-1
component name
XCSPR
head type
Turret head rotary axis
Complementary
Product certifications
CSA
UL
BG
Handle front plate colour
96 mm
Product or component type
Guard switch
[uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-5-1
cable entry
1 entry tapped for 1/2" NPT
cable outer diameter
7…10 mm
Enclosure material
Polyamide PA66 fibre glass impregnated
Clamping connection capacity
1 x 0.5...2 x 1.5 mm² with or without cable end
contact operation
Slow-break, break before make
Contacts type and composition
1 NC + 1 NO
Electrical shock protection class
Class II conforming to EN/IEC 61140
safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Material
Plastic
width (w)
30 mm
Type of operator
Spindle 30 mm
contact code designation
A300, AC-15 (Ue = 120 V, Ie = 6 A) conforming to EN/IEC 60947-5-1
A300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1
Q300, DC-13 (Ue = 125 V, Ie = 0.55 A) conforming to EN/IEC 60947-5-1
Q300, DC-13 (Ue = 250 V, Ie = 0.27 A) conforming to EN/IEC 60947-5-1
Net weight
0.105 kg
Lever material
Stainless steel
depth
60 mm
mechanical durability
1000000 cycles
Positive opening
With NC contact
electrical connection
Terminal
Maximum resistance across terminals
30 mOhm conforming to EN/IEC 60947-5-4
Minimum torque for tripping
0.1 N.m
Insulation
Double insulated
Positive opening minimum torque
0.25 N.m
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Poles description
2
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Short-circuit protection
10 A cartridge fuse type gG (gl)
Tripping angle
5 °
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP67 conforming to IEC 60529
Range of product
Telemecanique Safety switches XCS
ambient air temperature for operation
-25…70 °C
standards
EN/IEC 60947-5-1
EN/ISO 12100
UL 508
EN 1088/ISO 14119
EN/IEC 60947-5-4
CSA C22.2 No 14
EN/IEC 60204-1
vibration resistance
50 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TC
TH