Main
[ithe] thermal current under enclosure
6 A
Operator direction information
Centred
[ui] rated insulation voltage
300 V conforming to UL 508
300 V conforming to CSA C22.2 No 14
400 V (pollution degree 3) conforming to EN/IEC 60947-1
component name
XCSPL
head type
Turret head rotary lever
Complementary
Product certifications
BG
UL
CSA
Product or component type
Guard switch
[uimp] rated impulse withstand voltage
4 kV conforming to EN/IEC 60947-5-1
cable entry
1 entry tapped for Pg 11
cable outer diameter
7…10 mm
Enclosure material
Polyamide PA66 fibre glass impregnated
Clamping connection capacity
1 x 0.34...2 x 0.75 mm² with or without cable end
contact operation
Slow-break, break before make
Contacts type and composition
1 NC + 1 NC + 1 NO
Electrical shock protection class
Class II conforming to EN/IEC 61140
safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Material
Plastic
Type of operator
Elbowed flush lever
contact code designation
B300, AC-15 (Ue = 120 V, Ie = 6 A) conforming to EN/IEC 60947-5-1
B300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1
Q300, DC-13 (Ue = 125 V, Ie = 0.2 A) conforming to EN/IEC 60947-5-1
R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN/IEC 60947-5-1
Net weight
0.095 kg
Lever material
Stainless steel
mechanical durability
1000000 cycles
Positive opening
With NC contact
electrical connection
Terminal
Maximum resistance across terminals
30 mOhm conforming to EN/IEC 60947-5-4
Minimum actuation speed
0.1 m/s
Minimum torque for tripping
0.1 N.m
Insulation
Double insulated
Positive opening minimum torque
0.25 N.m
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Poles description
3
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Short-circuit protection
6 A cartridge fuse type gG (gl)
Tripping angle
5 °
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP67 conforming to IEC 60529
Range of product
Telemecanique Safety switches XCS
ambient air temperature for operation
-25…70 °C
standards
EN/IEC 60204-1
EN/IEC 60947-5-4
CSA C22.2 No 14
EN 1088/ISO 14119
EN/IEC 60947-5-1
UL 508
EN/ISO 12100
vibration resistance
50 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TH
TC