Main
design
Compact
[ithe] thermal current under enclosure
6 A
Protection technology
Plastic protective cover, secured by 5-lobe socket head safety screw
[ui] rated insulation voltage
300 V conforming to UL 508
400 V (pollution degree 3) conforming to EN/IEC 60947-1
300 V conforming to CSA C22.2 No 14
component name
XCSP
head type
Plunger head
Complementary
Product certifications
CSA
UL
Handle front plate colour
100 mm
Product or component type
Safety limit switch
[uimp] rated impulse withstand voltage
4 kV conforming to EN/IEC 60947-1
4 kV conforming to IEC 60664
cable entry
1 entry tapped for Pg 13.5
Enclosure material
Plastic
Clamping connection capacity
1 x 0.34...2 x 0.75 mm²
contact operation
Snap action
Contacts type and composition
1 NC + 1 NC + 1 NO
Electrical shock protection class
Class II conforming to NF C 20-030
Class II conforming to EN/IEC 61140
safety reliability data
B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
body material
Plastic
Material
Plastic
width (w)
34 mm
Type of operator
Steel roller plunger
Ik degree of protection
IK04 conforming to EN 50102
contact code designation
B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN/IEC 60947-5-1 appendix A
Net weight
0.255 kg
head material
Zamak
depth
35 mm
mechanical durability
10000000 cycles
repeat accuracy
0.1 mm on tripping points, 1 million operating cycles for head with end plunger
Maximum actuation speed
0.5 m/s
Positive opening
With NC contact
electrical connection
Terminal
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Minimum force for tripping
12 N
Switch actuation
By 30° cam
Positive opening minimum force
36 N
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Poles description
3
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Short-circuit protection
6 A cartridge fuse type gG (gl)
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
Range of product
Telemecanique Safety switches XCS
ambient air temperature for operation
-25…70 °C
standards
EN 1088/ISO 14119
CSA C22.2 No 14
UL 508
EN/IEC 60204-1
EN/IEC 60947-5-1
vibration resistance
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TC