Main
design
Miniature
Protection technology
Plastic protective cover, secured by 5-lobe socket head safety screw
cable length
2 m
[ui] rated insulation voltage
300 V conforming to UL 508
400 V (pollution degree 3) conforming to IEC 60947-5-1
300 V conforming to CSA C22.2 No 14
component name
XCSM
head type
Plunger head
Complementary
cable composition
9 x 0.34 mm²
Product certifications
CSA
UL
Handle front plate colour
60 mm
Product or component type
Safety limit switch
[uimp] rated impulse withstand voltage
4 kV conforming to IEC 60664
4 kV conforming to IEC 60947-1
contact operation
Snap action
Contacts type and composition
1 NC + 1 NC + 1 NO + 1 NO
Electrical shock protection class
Class I conforming to NF C 20-030
Class I conforming to EN/IEC 61140
Fixing mode
By the body
safety reliability data
B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
body material
Zamak
Material
Metal
width (w)
30 mm
Type of operator
Metal end plunger
Ik degree of protection
IK06 conforming to EN 50102
contact code designation
B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN 60947-5-1
B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN 60947-5-1
R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN/IEC 60947-5-1 appendix A
Net weight
0.165 kg
head material
Zamak
depth
16 mm
mechanical durability
10000000 cycles
repeat accuracy
0.05 mm on the tripping points
Maximum actuation speed
0.5 m/s
Positive opening
With NC contact
electrical connection
Pre-cabled
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Minimum actuation speed
0.01 m/min
Minimum force for tripping
8.5 N
Positive opening minimum force
42.5 N
Shock resistance
25 gn for 18 ms conforming to IEC 60068-2-27
Poles description
4
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Short-circuit protection
6 A cartridge fuse type gG (gl)
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
IP68 conforming to IEC 60529
Range of product
Telemecanique Safety switches XCS
ambient air temperature for operation
-25…70 °C
standards
EN/IEC 60947-5-1
EN/IEC 60204-1
CSA C22.2 No 14
EN 1088
UL 508
vibration resistance
5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TC