Complementary
																					
												cable composition
												9 x 0.34 mm²
											
                            
																					
												Product certifications
												CSA
UL
											
                            
																					
												Handle front plate colour
												70 mm
											
                            
																					
												Product or component type
												Safety limit switch
											
                            
																					
												[uimp] rated impulse withstand voltage
												4 kV conforming to IEC 60664
4 kV conforming to IEC 60947-1
											
                            
																					
												contact operation
												Snap action
											
                            
																					
												Contacts type and composition
												1 NC + 1 NC + 1 NO + 1 NO
											
                            
																					
												Electrical shock protection class
												Class I conforming to NF C 20-030
Class I conforming to EN/IEC 61140
											
                            
																					
												Fixing mode
												By the body
											
                            
																					
												safety reliability data
												B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
											
                            
																					
												body material
												Zamak
											
                            
																					
												Material
												Metal
											
                            
																					
												width (w)
												30 mm
											
                            
																					
												Type of operator
												Roller plunger
											
                            
																					
												Ik degree of protection
												IK06 conforming to EN 50102
											
                            
																					
												contact code designation
												B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN 60947-5-1
B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN 60947-5-1
R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN/IEC 60947-5-1 appendix A
											
                            
																					
												Net weight
												0.17 kg
											
                            
																					
												head material
												Zamak
											
                            
																					
												depth
												16 mm
											
                            
																					
												mechanical durability
												10000000 cycles
											
                            
																					
												repeat accuracy
												0.05 mm on the tripping points
											
                            
																					
												Maximum actuation speed
												0.5 m/s
											
                            
																					
												Positive opening
												With NC contact
											
                            
																					
												electrical connection
												Pre-cabled
											
                            
																					
												Maximum resistance across terminals
												25 MOhm conforming to IEC 60255-7 category 3
											
                            
																					
												Minimum actuation speed
												0.01 m/min
											
                            
																					
												Minimum force for tripping
												7 N
											
                            
																					
												Switch actuation
												By 30° cam
											
                            
																					
												Positive opening minimum force
												35 N
											
                            
																					
												Type of approach
												Lateral approach
											
                            
																					
												Shock resistance
												25 gn for 18 ms conforming to IEC 60068-2-27
											
                            
																					
												Poles description
												4
											
                            
																					
												Safety level
												Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
											
                            
																					
												Short-circuit protection
												6 A cartridge fuse type gG (gl)
											
                            
																			 
																	
										Environment
																					
												Ambient air temp for storage/transportation
												-40…70 °C
											
                            
																					
												ip degree of protection
												IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
IP68 conforming to IEC 60529
											
                            
																					
												Range of product
												Telemecanique Safety switches XCS
											
                            
																					
												ambient air temperature for operation
												-25…70 °C
											
                            
																					
												standards
												EN/IEC 60947-5-1
UL 508
EN/IEC 60204-1
EN 1088
CSA C22.2 No 14
											
                            
																					
												vibration resistance
												5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
											
                            
																					
												protective treatment
												TC