All categories
Compare Cart

XCSE8541 - Safety switch, Telemecanique Safety switches XCS, metal XCSE, 3NC, slow break, 2 entries tapped Pg 13, 220/240 V - Schneider Electric

Expected in 2-4 weeks
XCSE8541 - Safety switch, Telemecanique Safety switches XCS, metal XCSE, 3NC, slow break, 2 entries tapped Pg 13, 220/240 V - Schneider Electric - Safety switch, Telemecanique Safety switches XCS, metal XCSE, 3NC, slow break, 2 entries tapped Pg 13, 220/240 V - Schneider Electric - 0
XCSE8541 - Safety switch, Telemecanique Safety switches XCS, metal XCSE, 3NC, slow break, 2 entries tapped Pg 13, 220/240 V - Schneider Electric
537,33 € excl. VAT
655,54 € incl. VAT
Text About:
Safety switch, Telemecanique Safety switches XCS, metal XCSE, 3NC, slow break, 2 entries tapped Pg 13, 220/240 V - Schneider Electric
655,54 €
SPECIFICATIONS
Main
design Rectangular
[ithe] thermal current under enclosure 6 A
Signalling circuit voltage 110/240 V (voltage limits: 95...264 V)
Solenoid contacts type and composition 1 NC + 1 NO (slow-break, simultaneous)
[ui] rated insulation voltage 250 V conforming to EN/IEC 60947-1 for signalling circuit
component name XCSE
head type Key operated turret head
Complementary
[ie] rated operational current 0.55 A at 125 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
3 A at 120 V, AC-15, B300 conforming to EN/IEC 60947-5-1
1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1
[un] rated nominal voltage 220/240 V - 20...10 %
Product certifications UL
CSA
Handle front plate colour 146 mm
Product or component type Safety switch
[uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-5-1
Actuator forcible withdrawal rtc 2000 N
Load factor 1
cable entry 2 entries tapped for Pg 13.5
Locking options description With interlocking, locking by solenoid
cable outer diameter 9…12 mm
contact operation Slow-break, simultaneous
Contacts type and composition 3 NC
Electrical shock protection class Class I conforming to EN/IEC 61140
safety reliability data B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
body material Zamak
Material Metal
width (w) 98 mm
Local signalling 2 LEDs (green or orange) for guard open/guard closed and locked
Net weight 1.14 kg
head material Zamak
depth 44 mm
Electromagnet interlocking Locking on energisation and unlocking on de-energisation of solenoid
mechanical durability 1000000 cycles
Maximum actuation speed 0.5 m/s
Positive opening With NC contact
Power consumption in va 10 VA inrush
10 VA sealed
electrical connection Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Maximum operating rate 10 cyc/mn for maximum durability
Minimum actuation speed 0.01 m/s
Minimum actuator force for extraction 20 N
Shock resistance 10 gn for 11 ms conforming to IEC 60068-2-27
Poles description 3
Safety level Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Supply frequency 50/60 Hz
Signalling circuit type AC
Short-circuit protection 10 A cartridge fuse type gG (gl)
Protection type Overvoltage protection for signalling circuit
Signalling circuit consumption 7 mA
Supply voltage type AC/DC
Environment
Ambient air temp for storage/transportation -40…70 °C
ip degree of protection IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Range of product Telemecanique Safety switches XCS
ambient air temperature for operation -25…40 °C
standards EN/IEC 60947-5-1
CSA C22.2 No 14
UL 508
EN 1088/ISO 14119
EN/ISO 12100
EN/IEC 60204-1
vibration resistance 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment TC
Recently viewed
537,33 € excl. VAT
655,54 € incl. VAT
Expected in 2-4 weeks