Main
design
Rectangular
Signalling circuit voltage
24/48 V (voltage limits: 20...52 V)
Solenoid contacts type and composition
1 NC + 1 NO (slow-break, simultaneous)
component name
XCSE
head type
Key operated turret head
Complementary
Product certifications
CSAUL
Product or component type
Safety switch
[us] rated supply voltage
24 V - 20...10 %
cable entry
2 entries tapped for Pg 13.5
Locking options description
With interlocking, locking by solenoid
contact operation
Slow-break, break before make
Contacts type and composition
2 NC + 1 NO
Electrical shock protection class
Class I conforming to IEC 61140
safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
body material
Zamak
Material
Metal
Local signalling
2 LEDs (green or orange) for guard open/guard closed and locked
head material
Zamak
Electromagnet interlocking
Locking on energisation and unlocking on de-energisation of solenoid
Positive opening
With NC contact
electrical connection
Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Operating rate
10 cyc/mn for maximum durability
Shock resistance
10 gn for 11 ms conforming to IEC 60068-2-27
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach PL = e with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Supply frequency
50/60 Hz
Signalling circuit type
AC/DC
Protection type
Overvoltage protection for signalling circuit
Supply voltage type
AC/DC
Environment
ip degree of protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Range of product
Telemecanique Safety switches XCS
standards
CSA C22.2 No 14ISO 12100UL 508IEC 60947-5-1EN 1088/ISO 14119IEC 60204-1
vibration resistance
5 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
protective treatment
TC