Main
design
Rectangular, standard
cable length
2 m
[ui] rated insulation voltage
100 V DC
approach directions
3 directions
component name
XCSDMP
Complementary
[sa] assured operating distance
8 mm
[ue] rated operational voltage
24 V DC
cable composition
6 x 0.25 mm²
[ics] rated service breaking capacity
10 VA
Product certifications
UL
CSA
[sar] trigger distance
20 mm
Handle front plate colour
88 mm
Product or component type
Coded magnetic switch
[uimp] rated impulse withstand voltage
2.5 kV conforming to EN/IEC 60947-5-1
Contacts material
Rhodium
Enclosure material
Thermoplastic PBT
contact operation
1 NO staggered
Contacts type and composition
1 NC + 2 NO
Electrical shock protection class
Class II conforming to EN/IEC 61140
safety reliability data
B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
Material
Plastic
width (w)
25 mm
switching frequency
150 Hz
cable material
PVC
Net weight
0.18 kg
switching capacity in ma
0.1...100 mA
depth
13 mm
electrical durability
1200000 cycles
electrical connection
Pre-cabled
Maximum switching voltage
100 V DC
Maximum [ie] rated operational current
100 mA
Shock resistance
30 gn for 11 ms conforming to IEC 60068-2-27
Poles description
3
Resistance across terminals
10 Ohm
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Size
88 x 25 x 13 mm
Short-circuit protection
500 mA external cartridge fuse type gG (gl)
Environment
Ambient air temp for storage/transportation
-40…85 °C
ip degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
Maximum sensitivity to magnetic fields
0.3 mT
Range of product
Telemecanique Safety switches XCS
ambient air temperature for operation
-25…85 °C
standards
EN/ISO 12100
EN/IEC 60947-5-1
UL 508
ISO 14119
EN/IEC 60204-1
CSA C22.2 No 14
vibration resistance
10 gn (f= 10…150 Hz) conforming to IEC 60068-2-6
protective treatment
TH
insulation resistance
1000 MOhm