All categories
Compare Cart

XCSDMC7902 - Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMC, 2 NC, staggered, 2 m - Schneider Electric

Expected in 2-4 weeks EAN: 3389110971699
XCSDMC7902 - Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMC, 2 NC, staggered, 2 m - Schneider Electric - Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMC, 2 NC, staggered, 2 m - Schneider Electric - 0
EAN: 3389110971699
XCSDMC7902 - Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMC, 2 NC, staggered, 2 m - Schneider Electric
41,78 €
41,78 € incl. VAT
Text About:
Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMC, 2 NC, staggered, 2 m - Schneider Electric
41,78 €
SPECIFICATIONS
Main
conception Rectangulaire compact
product range Interrupteurs de sécurité Telemecanique XCS
reliability data B10d = 50000000 valeur pour une durée de vie de 20 ans limitée par l'usure ou le contact
type of product or equipment Interrupteur électromagnétique codé
cable length 2 m
[ui] rated insulation voltage 100 V CC
security level Jusqu'à catégorie 4 avec système de surveillance approprié et câblage correct se conformer à EN/ISO 13849-1
Jusqu'à PL = e avec système de surveillance approprié et câblage correct se conformer à EN/ISO 13849-1
Jusqu'à SIL 3 avec système de surveillance approprié et câblage correct se conformer à EN/CEI 61508
approach directions 3 directions
component name XCSDMC
Complementary
[ie] rated operational current 100 mA
[ue] rated operational voltage 24 V CC
cable composition 4 x 0,25 mm²
[his] scope of work 5 mm
[ics] rated service breaking capacity 10 VA
contact description 2 "O"
[sar] trigger distance 15 mm
Handle front plate colour 51 mm
[uimp] rated impulse withstand voltage 2,5 kV se conformer à EN/CEI 60947-5-1
case material PBT thermoplastique
dimension 51 x 16 x 7 mm
matter Plastique
product weight 0,101 kg
contact operation Échelonné
contact material Rhodium
width (w) 16 mm
switching frequency 150 Hz
cable material PVC
switching capacity in ma 0,1…100 mA
depth 7 mm
electrical stamina 1200000 cycle
electrical connection Pré-câblé
short circuit protection 500 mA fusible à cartouche externe type gG (gl)
resistance between terminals 10 Ohm
Poles description 2
maximum cut-off voltage 100 V CC
Environment
ip degree of protection IP66 se conformer à CEI 60529
IP67 se conformer à CEI 60529
product certificates CSA
UL
class of protection against electric shock Classe II se conformer à EN/CEI 61140
operating ambient temperature -25…85 °C
standards CSA C22.2 No 14
UL 508
EN/CEI 60947-5-1
EN/CEI 60204-1
EN/ISO 12100
ISO 14119
sensitivity to maximum magnetic fields 0,3 mT
storage room temperature -40…85 °C
mechanical shock resistance 30 gn pour 11 ms se conformer à CEI 60068-2-27
vibration resistance 10 gn (f= 10…150 Hz) se conformer à CEI 60068-2-6
protective treatment TH
insulation resistance 1000 MΩ
Recently viewed
41,78 €
41,78 € incl. VAT
Expected in 2-4 weeks