All categories
Compare Cart

XCSDMC591L01M8 - Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMC, 1 NC + 1 NO, staggered, M8 0.15 m - Schneider Electric

Expected in 2-4 weeks
XCSDMC591L01M8 - Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMC, 1 NC + 1 NO, staggered, M8 0.15 m - Schneider Electric - Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMC, 1 NC + 1 NO, staggered, M8 0.15 m - Schneider Electric - 0
XCSDMC591L01M8 - Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMC, 1 NC + 1 NO, staggered, M8 0.15 m - Schneider Electric
86,49 €
86,49 € incl. VAT
Text About:
Coded magnetic switch, Telemecanique Safety switches XCS, XCSDMC, 1 NC + 1 NO, staggered, M8 0.15 m - Schneider Electric
86,49 €
SPECIFICATIONS
Main
design Rectangular, compact
cable length 0.15 m
[ui] rated insulation voltage 100 V DC
approach directions 3 directions
component name XCSDMC
Complementary
[sa] assured operating distance 5 mm
[ue] rated operational voltage 24 V DC
[ics] rated service breaking capacity 3 VA
Product certifications UL
CSA
[sar] trigger distance 15 mm
Handle front plate colour 51 mm
Product or component type Coded magnetic switch
[uimp] rated impulse withstand voltage 2.5 kV conforming to EN/IEC 60947-5-1
Contacts material Rhodium
Enclosure material Thermoplastic PBT
contact operation Staggered
Contacts type and composition 1 NC + 1 NO
Electrical shock protection class Class II conforming to EN/IEC 61140
safety reliability data B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
Material Plastic
width (w) 16 mm
switching frequency 150 Hz
cable material PVC
Local signalling 1 LED
Net weight 0.101 kg
switching capacity in ma 5...100 mA
connector type M8
depth 7 mm
electrical durability 1200000 cycles
electrical connection Connector on flying lead
Maximum switching voltage 100 V DC
Maximum [ie] rated operational current 100 mA
Shock resistance 30 gn for 11 ms conforming to IEC 60068-2-27
Poles description 2
Resistance across terminals 57 Ohm
Safety level Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Size 51 x 16 x 7 mm
Short-circuit protection 500 mA external cartridge fuse type gG (gl)
Environment
Ambient air temp for storage/transportation -40…85 °C
ip degree of protection IP67 conforming to IEC 60529
Maximum sensitivity to magnetic fields 0.3 mT
Range of product Telemecanique Safety switches XCS
ambient air temperature for operation -25…85 °C
standards UL 508
EN/ISO 12100
CSA C22.2 No 14
ISO 14119
EN/IEC 60204-1
EN/IEC 60947-5-1
vibration resistance 10 gn (f= 10…150 Hz) conforming to IEC 60068-2-6
protective treatment TH
insulation resistance 1000 MOhm
Recently viewed
86,49 €
86,49 € incl. VAT
Expected in 2-4 weeks