Main
design
Industrial
[ithe] thermal current under enclosure
10 A
Signalling circuit voltage
24/48 V
[ui] rated insulation voltage
300 V conforming to UL 508
500 V conforming to EN/IEC 60947-1
300 V conforming to CSA C22.2 No 14
component name
XCSA
head type
Key operated turret head
Complementary
[ie] rated operational current
6 A at 120 V, AC-15, A300 conforming to EN/IEC 60947-5-1
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
Product certifications
CSA
UL
Handle front plate colour
114 mm
Product or component type
Safety switch
[uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-5-1
cable entry
1 entry tapped for 1/2" NPT
Locking options description
Without locking of actuator
contact operation
Slow-break, break before make
Contacts type and composition
2 NC + 1 NO
Electrical shock protection class
Class I conforming to EN/IEC 61140
safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
body material
Zamak
Material
Metal
width (w)
40 mm
Local signalling
1 LED (orange) for on opening of NC contacts
Net weight
0.44 kg
head material
Zamak
depth
44 mm
mechanical durability
1000000 cycles
Maximum actuation speed
0.5 m/s
Positive opening
With NC contact
electrical connection
Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Maximum operating rate
10 cyc/mn for maximum durability
Minimum actuation speed
0.01 m/s
Minimum actuator force for extraction
20 N
Shock resistance
10 gn for 11 ms conforming to IEC 60068-2-27
Poles description
3
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Signalling circuit type
AC/DC
Short-circuit protection
10 A cartridge fuse type gG (gl)
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Range of product
Telemecanique Safety switches XCS
ambient air temperature for operation
-25…70 °C
standards
EN/IEC 60204-1
CSA C22.2 No 14
EN/IEC 60947-5-1
EN/ISO 12100
UL 508
EN 1088/ISO 14119
vibration resistance
5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TC