Main
design
Industrial
Signalling circuit voltage
24/48 V
component name
XCSA
head type
Key operated turret head
Complementary
Product certifications
CSAUL
Product or component type
Safety switch
cable entry
1 entry tapped for Pg 13.5
Locking options description
Without locking of actuator
contact operation
Slow-break, break before make
Contacts type and composition
1 NC + 2 NO
Electrical shock protection class
Class I conforming to IEC 61140
safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
body material
Zamak
Material
Metal
Local signalling
1 LED (orange) for on opening of NC contacts
head material
Zamak
Positive opening
With NC contact
electrical connection
Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Operating rate
10 cyc/mn for maximum durability
Shock resistance
10 gn for 11 ms conforming to IEC 60068-2-27
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach PL = e with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Signalling circuit type
AC/DC
Environment
ip degree of protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Range of product
Telemecanique Safety switches XCS
standards
CSA C22.2 No 14ISO 12100UL 508IEC 60947-5-1EN 1088/ISO 14119IEC 60204-1
vibration resistance
5 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
protective treatment
TC