Complementary
Handle front plate colour
95 mm
Product or component type
Limit switch
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
cable entry
1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9…12 mm conforming to NF C 68-300
Contact block per direction [control circuit]
2 per direction
Contacts insulation form
Za
contact operation
Snap action
Contacts type and composition
2 C/O
Fixing mode
By the body
body material
Zinc alloy
Material
Metal
width (w)
85 mm
Type of operator
Spring return roller zinc plated steel with lever
contact code designation
A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A
Net weight
1.17 kg
depth
75 mm
mechanical durability
300000 cycles
electrical durability
5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Number of steps
2
Positive opening
Without
electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Minimum actuation speed
0.01 m/min
Maximum displacement angle
-90 °
90 °
Minimum torque for tripping
1 N.m
Movement of operating head
Rotary
Switch actuation
By conveyor belt
Type of approach
Lateral approach, 2 directions
Shock resistance
30 gn for 18 ms conforming to IEC 60068-2-27
Poles description
2
Sensor design
-
Short-circuit protection
10 A cartridge fuse, type gG
Tripping angle
10 ° for fault signalling
18 ° for stopping of the conveyor belt
Terminals description iso n°1
(11-12)NC
(13-14)NON
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP65 conforming to IEC 60529
Range of product
OsiSense XC
ambient air temperature for operation
-25…70 °C
overvoltage category
Class I conforming to IEC 61140
Class I conforming to NF C 20-030
standards
EN 60947-5-1
NF C 79-130
CSA C22.2 No 14
IEC 60947-5-1
IEC 60204-1
EN 60204-1
vibration resistance
9 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TC