Complementary
Cable entry number
1 tapped entry for Pg 13.5 cable gland (included) 9…12 mm
Product certifications
INERIS 04ATEX0014X
IEC-Ex INE 16.0048X
Handle front plate colour
95 mm
Product or component type
Limit switch
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
Contact block per direction [control circuit]
1 per direction
Contacts insulation form
Zb
marking
II2 D-Ex tb IIIC T85°C Db IP66/67
contact operation
Snap action
Contacts type and composition
2 x (1 NC + 1 NO)
Electrical shock protection class
Class I conforming to IEC 60536
Class I conforming to NF C 20-030
Fixing mode
By the body
Material
Metal
width (w)
85 mm
Type of operator
Stay put crossed rods lever metal square rod 6 mm
contact code designation
A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN 60947-5-1
A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to IEC 60947-5-1 appendix A
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN 60947-5-1
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
depth
75 mm
mechanical durability
10000000 cycles
electrical durability
5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C
Maximum actuation speed
1.5 m/s
Number of steps
1
Positive opening
With
electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
25 MOhm conforming to NF C 93-050 method A
Minimum actuation speed
0.01 m/min
Maximum displacement angle
-90 °
90 °
Minimum force for tripping
0.7 N
Minimum torque for tripping
0.6 N.m
Movement of operating head
Rotary
Switch actuation
By any moving part
Type of approach
Lateral approach, 2 directions
Shock resistance
68 gn conforming to IEC 60068-2-27
Poles description
4
Short-circuit protection
10 A cartridge fuse, type gG