Complementary
Product certifications
UL
CSA
Handle front plate colour
65 mm
Product or component type
Limit switch
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
cable entry
1 entry tapped for Pg 11 cable gland, cable outer diameter: 9…12 mm
Contacts insulation form
Zb
contact operation
Snap action
Contacts type and composition
1 NC + 1 NC
Fixing mode
By the body
body material
Plastic
Material
Plastic
width (w)
31 mm
Type of operator
Spring return roller plunger metal
Ik degree of protection
IK04 conforming to EN 50102
contact code designation
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A
Net weight
0.115 kg
head material
Zamak
depth
30 mm
electrical durability
5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
repeat accuracy
0.1 mm on the tripping points with 1 million operating cycles
Maximum actuation speed
0.5 m/s
Positive opening
With
electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Minimum force for tripping
12 N
Movement of operating head
Linear
Switch actuation
By 30° cam
Positive opening minimum force
36 N
Type of approach
Lateral approach, 2 directions
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Poles description
2
Sensor design
Compact
Short-circuit protection
10 A cartridge fuse, type gG
Terminals description iso n°1
(11-12)NC
(21-22)NC
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
Range of product
Telemecanique Limit switches XC Standard
ambient air temperature for operation
-25…70 °C
overvoltage category
Class II conforming to IEC 61140
Class II conforming to NF C 20-030
standards
IEC 60204-1
IEC 60947-5-1
CSA C22.2 No 14
EN 60204-1
UL 508
EN 60947-5-1
vibration resistance
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TC