Main
Body type
Fixed
Device short name
XCNT
[ui] rated insulation voltage
300 V conforming to UL 508
500 V (pollution degree 3) conforming to IEC 60947-1
300 V conforming to CSA C22.2 No 14
Series name
Standard format
head type
Plunger head
Complementary
Product certifications
CCC
CSA
UL
Handle front plate colour
86.17 mm
Product or component type
Limit switch
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
cable entry
2 entries tapped for M16 x 1.5 cable gland, cable outer diameter: 7…13 mm
Contacts insulation form
Zb
contact operation
Snap action
Contacts type and composition
1 NC + 1 NO
Electrical shock protection class
Class II conforming to IEC 61140
Class II conforming to NF C 20-030
Fixing mode
By the body
body material
Plastic
Material
Plastic
width (w)
58.8 mm
Type of operator
Spring return roller lever plunger thermoplastic
Ik degree of protection
IK04 conforming to EN 50102
contact code designation
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5-1 appendix A
head material
Plastic
depth
30.5 mm
mechanical durability
10000000 cycles
Maximum actuation speed
1 m/s
electrical connection
Screw-clamp open terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Movement of operating head
Linear
Switch actuation
By 30° cam
Type of approach
Lateral approach, 1 direction
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Poles description
2
Sensor design
Compact
Short-circuit protection
10 A cartridge fuse, type gG
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP65 conforming to IEC 60529
Range of product
Telemecanique Limit switches XC Standard
ambient air temperature for operation
-25…70 °C
standards
EN/IEC 60947-5-1
CSA C22.2 No 14
UL 508
EN/IEC 60204-1
vibration resistance
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TC