Complementary
cable composition
4 x 0.75 mm²
Product certifications
UL
CCC
CSA
Handle front plate colour
232 mm
Product or component type
Limit switch
[uimp] rated impulse withstand voltage
4 kV conforming to IEC 60664
4 kV conforming to IEC 60947-1
Contacts insulation form
Zb
contact operation
Snap action
Contacts type and composition
1 NC + 1 NO
Electrical shock protection class
Class II conforming to IEC 61140
Class II conforming to NF C 20-030
Fixing mode
By the body
body material
Plastic
Material
Plastic
width (w)
30 mm
Type of operator
Spring return round rod lever thermoplastic round rod 6 mm, L = 200 mm
Ik degree of protection
IK04 conforming to EN 50102
contact code designation
B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5-1 appendix A
Net weight
0.08 kg
head material
Zamak
depth
16 mm
mechanical durability
5000000 cycles
electrical durability
5000000 cycles, DC-13, 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Maximum actuation speed
1.5 m/s
Positive opening
Without
electrical connection
Fixed cable
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Minimum force for tripping
0.1 N
Movement of operating head
Rotary
Switch actuation
By any moving part
Type of approach
Lateral approach
Shock resistance
25 gn for 18 ms conforming to IEC 60068-2-27
Poles description
2
Sensor design
Miniature
Short-circuit protection
6 A cartridge fuse, type gG
Wire insulation material
PvR
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP65 conforming to IEC 60529
Range of product
Telemecanique Limit switches XC Standard
ambient air temperature for operation
-25…70 °C
standards
UL 508
CSA C22.2 No 14
EN/IEC 60947-5-1
EN/IEC 60204-1
vibration resistance
5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TC