Complementary
cable composition
5 x 0.75 mm²
Product certifications
CSA
CCC
UL
Handle front plate colour
50 mm
Product or component type
Limit switch
[uimp] rated impulse withstand voltage
4 kV conforming to IEC 60664
4 kV conforming to IEC 60947-1
Contacts insulation form
Zb
contact operation
Slow-break
Contacts type and composition
1 NC + 1 NO
Fixing mode
By the head
body material
Zamak
Material
Metal
width (w)
30 mm
Type of operator
Spring return roller plunger metal
Ik degree of protection
IK06 conforming to EN 62262
contact code designation
B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5-1 appendix A
Net weight
0.205 kg
head material
Zamak
depth
16 mm
mechanical durability
10000000 cycles
electrical durability
5000000 cycles, DC-13, 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Maximum actuation speed
10 cm/s
Positive opening
With
electrical connection
Removable cable connector
Maximum resistance across terminals
25 mOhm conforming to IEC 60255-7 category 3
Minimum force for tripping
7 N
Movement of operating head
Linear
Switch actuation
By 30° cam
Positive opening minimum force
35 N
Type of approach
Lateral approach, 2 directions
Shock resistance
25 gn for 18 ms conforming to IEC 60068-2-27
Poles description
2
Sensor design
Miniature
Short-circuit protection
6 A cartridge fuse, type gG
Wire insulation material
PvR
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
IP68 conforming to IEC 60529
Range of product
Telemecanique Limit switches XC Standard
ambient air temperature for operation
-25…70 °C
overvoltage category
Class I conforming to IEC 61140
Class I conforming to NF C 20-030
standards
EN/IEC 60204-1
UL 508
EN/IEC 60947-5-1
CSA C22.2 No 14
vibration resistance
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TC