Complementary
[ie] rated operational current
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
Handle front plate colour
77 mm
Product or component type
Limit switch
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
cable entry
1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9…12 mm
Contacts insulation form
Zb
contact operation
Snap action
Contacts type and composition
1 NC + 1 NO
Fixing mode
By the body
body material
Zamak
Material
Metal
width (w)
40 mm
Type of operator
Spring return roller lever metal ball bearing mounted
Ik degree of protection
IK07 conforming to IEC 62262
Net weight
0.49 kg
head material
Zamak
depth
44 mm
mechanical durability
30000000 cycles
electrical durability
5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Maximum actuation speed
1.5 m/s
Number of steps
1
Positive opening
With
electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Minimum torque for tripping
0.25 N.m
Movement of operating head
Rotary
Switch actuation
By 30° cam
Positive opening minimum torque
0.35 N.m
Type of approach
Lateral approach, 1 or 2 programmable direction
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Poles description
2
Sensor design
Form A conforming to CENELEC EN 50041
Short-circuit protection
10 A cartridge fuse, type gG
Terminals description iso n°1
(13-14)NON !@ !(21-22)NC
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP66 conforming to IEC 60529
Range of product
Telemecanique Limit switches XC Standard
ambient air temperature for operation
-25…70 °C
overvoltage category
Class I conforming to IEC 61140
standards
CENELEC EN 50041
EN/IEC 60947-5-1
EN 60204-1
vibration resistance
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6