Complementary
Product certifications
CSA
UL
CCC
Handle front plate colour
129 mm
Product or component type
Limit switch
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
cable entry
1 entry tapped for M20 x 1.5 cable gland, cable outer diameter: 7…13 mm
Contacts insulation form
Zb
contact operation
Slow-break, simultaneous
Contacts type and composition
2 NC
Electrical shock protection class
Class II conforming to IEC 61140
Class II conforming to NF C 20-030
Fixing mode
By the body
body material
Plastic
Material
Plastic
width (w)
40 mm
Type of operator
Spring return roller lever thermoplastic
Ik degree of protection
IK03 conforming to EN 50102
contact code designation
A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A
Net weight
0.145 kg
head material
Plastic
depth
60 mm
mechanical durability
20000000 cycles
electrical durability
5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Maximum actuation speed
1.5 m/s
Number of steps
1
Positive opening
With
electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Minimum actuation speed
6 m/min
Minimum torque for tripping
0.1 N.m
Movement of operating head
Rotary
Switch actuation
By 30° cam
Positive opening minimum torque
0.3 N.m
Type of approach
Lateral approach, 1 or 2 programmable direction
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Poles description
2
Sensor design
Form A conforming to CENELEC EN 50041
Short-circuit protection
10 A cartridge fuse, type gG
Terminals description iso n°1
(21-22)NC
(11-12)NC
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP65 conforming to IEC 60529
Range of product
Telemecanique Limit switches XC Standard
ambient air temperature for operation
-25…70 °C
overvoltage category
Class II conforming to IEC 61140
Class II conforming to NF C 20-030
standards
IEC 60204-1
EN 60947-5-1
UL 508
CENELEC EN 50041
CSA C22.2 No 14
IEC 60947-5-1
EN 60204-1
vibration resistance
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TC