Complementary
Product certifications
CSA
CCC
UL
Handle front plate colour
65 mm
Product or component type
Limit switch
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
cable entry
1 entry tapped for M16 x 1.5 cable gland, cable outer diameter: 4…8 mm
Contacts insulation form
Zb
contact operation
Snap action
Contacts type and composition
1 NC + 1 NO
Electrical shock protection class
Class II conforming to IEC 61140
Class II conforming to NF C 20-030
Fixing mode
By the body
body material
Plastic
Material
Plastic
width (w)
31 mm
Type of operator
Spring return roller lever plunger thermoplastic
Ik degree of protection
IK04 conforming to EN 50102
contact code designation
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A
Net weight
0.1 kg
head material
Zamak
depth
30 mm
mechanical durability
15000000 cycles
electrical durability
5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
repeat accuracy
0.1 mm on the tripping points with 1 million operating cycles
Maximum actuation speed
1 m/s
Positive opening
With
electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Minimum force for tripping
6 N
Movement of operating head
Linear
Switch actuation
By 30° cam
Positive opening minimum force
18 N
Type of approach
Vertical approach, 1 direction
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Poles description
2
Sensor design
Compact
Short-circuit protection
10 A cartridge fuse, type gG
Terminals description iso n°1
(21-22)NC
(13-14)NON
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
Range of product
Telemecanique Limit switches XC Standard
ambient air temperature for operation
-25…70 °C
standards
UL 508
IEC 60947-5-1
EN 60204-1
EN 60947-5-1
CSA C22.2 No 14
IEC 60204-1
vibration resistance
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TC