Complementary
[ie] rated operational current
3 A at 240 V, AC-15 conforming to EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13 conforming to EN/IEC 60947-5-1 appendix A
Product certifications
CSA
CCC
UL
Handle front plate colour
65 mm
Product or component type
Limit switch
[uimp] rated impulse withstand voltage
2.5 kV conforming to IEC 60664
2.5 kV conforming to IEC 60947-1
Contacts insulation form
Zb
contact operation
Snap action
Contacts type and composition
1 NC + 1 NO
Electrical shock protection class
Class II conforming to IEC 61140
Class II conforming to NF C 20-030
Fixing mode
By the body
body material
Plastic
Material
Plastic
width (w)
31 mm
Type of operator
Spring return cat''s whisker
Ik degree of protection
IK04 conforming to EN 50102
head material
Zamak
depth
30 mm
mechanical durability
5000000 cycles
electrical durability
5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Maximum actuation speed
1 m/s
Positive opening
Without
electrical connection
Male connector M12, 4 pins
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Minimum torque for tripping
13 N.m
Movement of operating head
Multi-directional
Switch actuation
By any moving part
Type of approach
Multi-directional approach
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Poles description
2
Sensor design
Compact
Short-circuit protection
4 A cartridge fuse, type gG
Terminals description iso n°1
(21-22)NC
(13-14)NON
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
Range of product
Telemecanique Limit switches XC Standard
ambient air temperature for operation
-25…70 °C
standards
EN 60204-1
IEC 60204-1
EN 60947-5-1
CSA C22.2 No 14
IEC 60947-5-1
UL 508
vibration resistance
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TC