Complementary
Product certifications
CSA
UL
CCC
Handle front plate colour
90…190 mm
Product or component type
Limit switch
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
cable entry
1 entry tapped for M20 x 1.5 cable gland, cable outer diameter: 7…13 mm
Contacts insulation form
Zb
contact operation
Snap action
Contacts type and composition
1 NC + 1 NO
Fixing mode
By the body
body material
Plastic
Material
Plastic
width (w)
30 mm
Type of operator
Spring return square rod lever metal square rod 3 mm, L = 125 mm
Ik degree of protection
IK04 conforming to EN 50102
contact code designation
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN/IEC 60947-5-1 appendix A
Net weight
0.18 kg
head material
Plastic
depth
42 mm
mechanical durability
10000000 cycles
electrical durability
5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Maximum actuation speed
1.5 m/s
Positive opening
With
electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Minimum torque for tripping
0.1 N.m
Movement of operating head
Rotary
Switch actuation
By any moving part
Positive opening minimum torque
0.15 N.m
Type of approach
Lateral approach, 2 directions
Shock resistance
45 gn for 11 ms conforming to IEC 60068-2-27
Poles description
2
Sensor design
Compact
Short-circuit protection
10 A cartridge fuse, type gG
Terminals description iso n°1
(13-14)NON !@ !(21-22)NC
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP65 conforming to IEC 60529
Range of product
Telemecanique Limit switches XC Standard
ambient air temperature for operation
-25…70 °C
overvoltage category
Class II conforming to IEC 61140
Class II conforming to NF C 20-030
standards
EN 60947-5-1
UL 508
IEC 60947-5-1
CSA C22.2 No 14
IEC 60204-1
EN 60204-1
vibration resistance
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TC