Complementary
Cable entry number
1 tapped entry for M20 x 1.5 cable gland (included) 7…13 mm
2 tapped entry for M20 x 1.5 cable gland
Product certifications
INERIS 04ATEX0014X
IEC-Ex INE 17.0020X
Handle front plate colour
77 mm
Product or component type
Limit switch
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
Contact block per direction [control circuit]
1 per direction
Contacts insulation form
Zb
marking
II2 D-Ex tb IIIC T85°C Db IP66/67
contact operation
Slow-break, staggered
Contacts type and composition
2 x (2 NC)
Electrical shock protection class
Class I conforming to IEC 60536
Class I conforming to NF C 20-030
Fixing mode
By the body
Material
Metal
width (w)
118 mm
Type of operator
Stay put crossed rods lever metal square rod 6 mm, L = 200 mm
contact code designation
A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN 60947-5-1
A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to IEC 60947-5-1 appendix A
Q150, DC-13 (Ue = 125 V), Ie = 0.55 A conforming to EN 60947-5-1
Q150, DC-13 (Ue = 125 V), Ie = 0.55 A conforming to IEC 60947-5-1 appendix A
depth
59 mm
mechanical durability
2000000 cycles
Maximum actuation speed
1.5 m/s
Number of steps
2
Positive opening
With
electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
25 MOhm conforming to NF C 93-050 method A
Minimum actuation speed
6 m/min
Maximum displacement angle
-180 °
180 °
Minimum torque for tripping
0.5 N.m
Movement of operating head
Rotary
Switch actuation
By any moving part
Type of approach
Lateral approach, 2 directions
Shock resistance
50 gn conforming to IEC 60068-2-27
Poles description
4
Short-circuit protection
10 A cartridge fuse, type gG
Environment
Directives
2014/34/EU - ATEX directive
ip degree of protection
IP66 conforming to IEC 60529
Range of product
Telemecanique Limit switches XC Standard
ambient air temperature for operation
-20…60 °C
Dust zone
Zone 21 - 22
standards
EN/IEC 60079-31
EN/IEC 60079-0
vibration resistance
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TC