Complementary
Cable entry number
1 tapped entry for M20 x 1.5 cable gland (included) 9…12 mm
Product certifications
INERIS 04ATEX0014X
IEC-Ex INE 17.0020X
Handle front plate colour
77 mm
Product or component type
Limit switch
[uimp] rated impulse withstand voltage
4 kV conforming to IEC 60664
4 kV conforming to IEC 60947-1
Contacts insulation form
Zb
marking
II2 D-Ex tb IIIC T85°C Db IP66/67
contact operation
Snap action
Contacts type and composition
2 NC + 1 NO
Electrical shock protection class
Class I conforming to IEC 61140
Class I conforming to NF C 20-030
Fixing mode
By the body
body material
Zamak
Material
Metal
width (w)
40 mm
Type of operator
Spring return roller plunger steel reinforced
contact code designation
B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN 60947-5-1
B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN 60947-5-1
R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to IEC 60947-5-1 appendix A
head material
Zamak
depth
44 mm
mechanical durability
25000000 cycles
electrical durability
5000000 cycles, DC-13, inductive load type, 120 V, 2 W, operating rate <3600 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 24 V, 4 W, operating rate <3600 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 3 W, operating rate <3600 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C
Maximum actuation speed
1 m/s
Number of steps
1
Positive opening
With
electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 0.75 mm²
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Minimum actuation speed
0.01 m/min
Minimum force for tripping
16 N
Movement of operating head
Linear
Switch actuation
By 30° cam
Positive opening minimum force
40 N
Type of approach
Lateral approach, 2 directions
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Poles description
3
Sensor design
Form C conforming to CENELEC EN 50041
Short-circuit protection
6 A cartridge fuse, type gG