Main
Body type
Fixed
Device short name
XCKJ
[ithe] thermal current under enclosure
4 A
[ui] rated insulation voltage
60 V (pollution degree 3) conforming to IEC 60947-1
Series name
Standard format
head type
Plunger head
Complementary
[ie] rated operational current
0.27 A at 50 V, DC-13 conforming to EN/IEC 60947-5-1 appendix A
3 A at 50 V, AC-15 conforming to EN/IEC 60947-5-1 appendix A
Product certifications
UL
CCC
CSA
Handle front plate colour
89 mm
Product or component type
Limit switch
[uimp] rated impulse withstand voltage
0.8 kV conforming to IEC 60664
0.8 kV conforming to IEC 60947-1
Contacts insulation form
Zb
contact operation
Snap action
Contacts type and composition
1 NC + 1 NO
Fixing mode
By the body
body material
Zamak
Material
Metal
width (w)
40 mm
Type of operator
Spring return plunger metal ball bearing mounted
Ik degree of protection
IK07 conforming to EN 50102
head material
Zamak
depth
44 mm
electrical durability
5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
repeat accuracy
0.1 mm on the tripping points with 1 million operating cycles
Maximum actuation speed
10 cm/s
Number of steps
1
Positive opening
With
electrical connection
Male connector M12, 5 pins
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Movement of operating head
Linear
Switch actuation
On end
Positive opening minimum torque
0.5 N.m
Type of approach
Vertical approach, 1 direction
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Poles description
2
Sensor design
-
Short-circuit protection
4 A cartridge fuse, type gG
Terminals description iso n°1
(21-22)NC
(13-14)NON
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP66 conforming to IEC 60529
Range of product
Telemecanique Limit switches XC Standard
ambient air temperature for operation
-25…70 °C
overvoltage category
Class I conforming to IEC 61140
Class I conforming to NF C 20-030
standards
CSA C22.2 No 14
EN 60947-5-1
UL 508
IEC 60947-5-1
EN 60204-1
IEC 60204-1
CENELEC EN 50041
vibration resistance
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TH