Complementary
[ie] rated operational current
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
Product certifications
UL
CSA
CCC
Handle front plate colour
77 mm
Product or component type
Limit switch
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664
6 kV conforming to IEC 60947-1
cable entry
1 entry tapped for 1/2" NPT cable gland
Contacts insulation form
Zb
contact operation
Snap action
Contacts type and composition
1 NC + 1 NO
Fixing mode
By the body
body material
Zamak
Material
Metal
width (w)
40 mm
Type of operator
Spring return round rod lever thermoplastic round rod 6 mm, L = 200 mm
Ik degree of protection
IK07 conforming to EN 50102
Net weight
0.485 kg
head material
Zamak
depth
44 mm
mechanical durability
30000000 cycles
electrical durability
5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Maximum actuation speed
1.5 m/s
Number of steps
1
Positive opening
Without
electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Minimum torque for tripping
0.25 N.m
Movement of operating head
Rotary
Switch actuation
By any moving part
Type of approach
Lateral approach, 1 or 2 programmable direction
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Poles description
2
Sensor design
Form D conforming to CENELEC EN 50041
Short-circuit protection
10 A cartridge fuse, type gG
Terminals description iso n°1
(13-14)NON !@ !(21-22)NC
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP66 conforming to IEC 60529
Range of product
Telemecanique Limit switches XC Standard
ambient air temperature for operation
-25…70 °C
overvoltage category
Class I conforming to IEC 61140
Class I conforming to NF C 20-030
standards
CSA C22.2 No 14
CENELEC EN 50041
IEC 60204-1
UL 508
EN 60947-5-1
EN 60204-1
IEC 60947-5-1
vibration resistance
25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TH