SPECIFICATIONS
Main
Body type Fixed
Device short name XCKD
[ithe] thermal current under enclosure 6 A AC
[ui] rated insulation voltage 300 V conforming to UL 508
400 V (pollution degree 3) conforming to IEC 60947-1
300 V conforming to CSA C22.2 No 14
Series name Standard format
head type Rotary head
Complementary
Cable entry number 1 tapped entry for M16 x 1.5 cable gland (included) 4…8 mm
Product certifications INERIS 04ATEX0014X
IEC-Ex INE 17.0020X
Handle front plate colour 65 mm
Product or component type Limit switch
[uimp] rated impulse withstand voltage 4 kV conforming to IEC 60664
4 kV conforming to IEC 60947-1
Contacts insulation form Zb
marking II2 D-Ex tb IIIC T85°C Db IP66/67
contact operation Snap action
Contacts type and composition 2 NC + 1 NO
Electrical shock protection class Class I conforming to IEC 61140
Class I conforming to NF C 20-030
Fixing mode By the body
body material Zamak
Material Metal
width (w) 31 mm
Type of operator Spring return roller lever thermoplastic variable length, roller diameter 50 mm
contact code designation B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN 60947-5-1
B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to EN 60947-5-1
R300, DC-13 (Ue = 250 V), Ie = 0.1 A conforming to IEC 60947-5-1 appendix A
head material Zamak
depth 30 mm
mechanical durability 10000000 cycles
electrical durability 5000000 cycles, DC-13, inductive load type, 120 V, 2 W, operating rate <3600 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 24 V, 4 W, operating rate <3600 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, inductive load type, 48 V, 3 W, operating rate <3600 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C
Maximum actuation speed 1.5 m/s
Number of steps 1
Positive opening With
electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 0.75 mm²
Maximum resistance across terminals 25 MOhm conforming to IEC 60255-7 category 3
Minimum actuation speed 0.01 m/min
Minimum torque for tripping 0.1 N.m
Movement of operating head Rotary
Switch actuation By 30° cam
Positive opening minimum torque 0.25 N.m
Type of approach Lateral approach, 2 directions
Shock resistance 50 gn for 11 ms conforming to IEC 60068-2-27
Poles description 3
Sensor design Compact
Short-circuit protection 6 A cartridge fuse, type gG
Environment
Directives 2014/34/EU - ATEX directive
ip degree of protection IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
Range of product Telemecanique Limit switches XC Standard
ambient air temperature for operation -20…60 °C
Dust zone Zone 21 - 22
standards EN/IEC 60079-31
EN/IEC 60079-0
vibration resistance 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment TC